SUN HYDRAULICS
FRDCCIN
$127.78 USD
- SUN HYDRAULICS
- Material:FRDCCIN
- Model:FRDC-CIN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDCCIN (Material Number: FRDCCIN) is a modified version of the FRDA valve, designed to control flow exclusively in bypass mode. This modification enhances system stability under specific conditions by ensuring that if bypass pressure surpasses the priority port pressure, the priority flow ceases to be pressure compensated. Customers must specify a flow rating, with factory settings accurate within 10% of the requested value. The valve features a sharp-edged orifice design that minimizes flow variations due to changes in viscosity and includes an adjustable control option allowing up to 25% variation from the nominal factory preset flow using a three-turn adjust screw. The maximum pressure at port 3 should not exceed 3000 psi (210 bar), and bypass flow becomes available only after fulfilling priority flow requirements. The valve incorporates Sun's floating style construction, reducing the risk of internal part binding due to excessive installation torque or machining variations. It fits into cavity T2A, belongs to Series 2, and has a capacity of 12 gpm (45 L/min) with a maximum operating pressure of 5000 psi (350 bar). The maximum input flow is rated at 30 gpm (120 L/min). Its hex size is 1-1/8 inches (28.6 mm), with an installation torque between 45 and 50 lbf.ft (61-68 Nm). The adjustment screw has an internal hex size of 5/32 inches (4 mm), while the locknut requires a torque of 80-90 lbf.in (9-10 Nm). The model weighs .40 lb (.20 kg) and uses Viton seal kits for cartridge sealing. This valve acts as a two-port restrictive flow control if the bypass port is blocked and maintains accuracy within \u00b110%, though it is set to \u00b15% during production testing for optimal performance in varying conditions.
The Sun Hydraulics FRDCCIN (Material Number: FRDCCIN) is a modified version of the FRDA valve, designed to control flow exclusively in bypass mode. This modification enhances system stability under specific conditions by ensuring that if bypass pressure surpasses the priority port pressure, the priority flow ceases to be pressure compensated. Customers must specify a flow rating, with factory settings accurate within 10% of the requested value. The valve features a sharp-edged orifice design that minimizes flow variations due to changes in viscosity and includes an adjustable control option allowing up to 25% variation from the nominal factory preset flow using a three-turn adjust screw. The maximum pressure at port 3 should not exceed 3000 psi (210 bar), and bypass flow becomes available only after fulfilling priority flow requirements. The valve incorporates Sun's floating style construction, reducing the risk of internal part binding due to excessive installation torque or machining variations. It fits into cavity T2A, belongs to Series 2, and has a capacity of 12 gpm (45 L/min) with a maximum operating pressure of 5000 psi (350 bar). The maximum input flow is rated at 30 gpm (120 L/min). Its hex size is 1-1/8 inches (28.6 mm), with an installation torque between 45 and 50 lbf.ft (61-68 Nm). The adjustment screw has an internal hex size of 5/32 inches (4 mm), while the locknut requires a torque of 80-90 lbf.in (9-10 Nm). The model weighs .40 lb (.20 kg) and uses Viton seal kits for cartridge sealing. This valve acts as a two-port restrictive flow control if the bypass port is blocked and maintains accuracy within \u00b110%, though it is set to \u00b15% during production testing for optimal performance in varying conditions.
This valve is a modification of an FRDA. It controls flow in the bypass mode only. If the bypass pressure exceeds the pressure at the priority port the priority flow will no longer be pressure compensated. This modification was done in an attempt to improve system stability in specific cases.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Bypass flow is not available until priority flow requirements are satisfied.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ