SUN HYDRAULICS
FRDCLAV
$128.77 USD
- SUN HYDRAULICS
- Material:FRDCLAV
- Model:FRDC-LAV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDCLAV (Material Number: FRDCLAV) is a specialized flow control valve designed for applications requiring precise flow management in bypass mode. This valve is a modification of the FRDA model, tailored to enhance system stability under specific conditions by ensuring that priority flow is not pressure compensated when bypass pressure surpasses the priority port pressure. The valve's design includes a sharp-edged orifice to minimize flow variations due to viscosity changes, making it highly reliable in various fluid conditions. Customers must specify a flow rating for factory settings, which are accurate within 10% of the requested value. The FRDCLAV features a maximum operating pressure of 5000 psi (350 bar) and can handle a maximum input flow of 30 gpm (120 L/min). It operates within a capacity of 12 gpm (45 L/min) and is constructed using Sun's floating style to prevent internal part binding caused by excessive installation torque or machining variations. A tuneable adjustment control option allows up to 25% variation from the nominal factory preset flow, adjustable via three turns of an internal hex screw. For installation, the valve requires a cavity type T-2A and has specific torque requirements: 45-50 lbf ft (61-68 Nm) for installation and 80-90 lbf in (9-10 Nm) for its locknut. The hex sizes for the valve and adjustment screw are 1 1/8 in. (28.6 mm) and 5/32 in. (4 mm), respectively, with a locknut hex size of 9/16 in. (15 mm). The model weighs approximately .40 lb (.20 kg) and comes with Viton seal kits for enhanced durability. This product is ideal for applications where precise control over hydraulic fluid distribution is critical, ensuring optimal performance across varying pressure conditions while maintaining system stability and efficiency.
The Sun Hydraulics FRDCLAV (Material Number: FRDCLAV) is a specialized flow control valve designed for applications requiring precise flow management in bypass mode. This valve is a modification of the FRDA model, tailored to enhance system stability under specific conditions by ensuring that priority flow is not pressure compensated when bypass pressure surpasses the priority port pressure. The valve's design includes a sharp-edged orifice to minimize flow variations due to viscosity changes, making it highly reliable in various fluid conditions. Customers must specify a flow rating for factory settings, which are accurate within 10% of the requested value. The FRDCLAV features a maximum operating pressure of 5000 psi (350 bar) and can handle a maximum input flow of 30 gpm (120 L/min). It operates within a capacity of 12 gpm (45 L/min) and is constructed using Sun's floating style to prevent internal part binding caused by excessive installation torque or machining variations. A tuneable adjustment control option allows up to 25% variation from the nominal factory preset flow, adjustable via three turns of an internal hex screw. For installation, the valve requires a cavity type T-2A and has specific torque requirements: 45-50 lbf ft (61-68 Nm) for installation and 80-90 lbf in (9-10 Nm) for its locknut. The hex sizes for the valve and adjustment screw are 1 1/8 in. (28.6 mm) and 5/32 in. (4 mm), respectively, with a locknut hex size of 9/16 in. (15 mm). The model weighs approximately .40 lb (.20 kg) and comes with Viton seal kits for enhanced durability. This product is ideal for applications where precise control over hydraulic fluid distribution is critical, ensuring optimal performance across varying pressure conditions while maintaining system stability and efficiency.
This valve is a modification of an FRDA. It controls flow in the bypass mode only. If the bypass pressure exceeds the pressure at the priority port the priority flow will no longer be pressure compensated. This modification was done in an attempt to improve system stability in specific cases.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Bypass flow is not available until priority flow requirements are satisfied.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ