SUN HYDRAULICS
FRDDCBN
$100.27 USD
- SUN HYDRAULICS
- Material:FRDDCBN
- Model:FRDD-CBN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FRDDCBN (Material Number: FRDDCBN) is a bypass restrictive, fixed orifice, priority flow control valve designed to manage input flow effectively. It directs the necessary priority flow through port 3 while bypassing any excess through port 2, which can be utilized in secondary circuits. This model is highly damped compared to the FRDA model, addressing potential system instability issues. Users must specify their desired flow rating, with factory settings offering a precision of within 10% of the requested value. The valve is capable of handling maximum pressures up to 5000 psi (350 bar) and supports an input flow of up to 30 gpm (120 L/min). The priority and bypass flows are both usable at system operating pressure levels, with priority flow remaining consistent despite input variations. The design features a sharp-edged orifice that minimizes viscosity-related flow variations and incorporates Sun's floating style construction to reduce internal binding risks due to installation torque or machining discrepancies. An optional tuneable adjustment control allows for a 25% variation from the nominal preset flow via a simple three-turn adjust screw mechanism. The valve fits into a T-2A cavity and requires specific hex sizes for installation and adjustment purposes: a valve hex size of 1-1/8 inches (28.6 mm), an internal hex size for the adjustment screw of 5/32 inches (4 mm), and a locknut hex size of 9/16 inches (15 mm). This model weighs approximately .40 lb (0.20 kg) and comes with Viton seal options for enhanced durability.
The Sun Hydraulics FRDDCBN (Material Number: FRDDCBN) is a bypass restrictive, fixed orifice, priority flow control valve designed to manage input flow effectively. It directs the necessary priority flow through port 3 while bypassing any excess through port 2, which can be utilized in secondary circuits. This model is highly damped compared to the FRDA model, addressing potential system instability issues. Users must specify their desired flow rating, with factory settings offering a precision of within 10% of the requested value. The valve is capable of handling maximum pressures up to 5000 psi (350 bar) and supports an input flow of up to 30 gpm (120 L/min). The priority and bypass flows are both usable at system operating pressure levels, with priority flow remaining consistent despite input variations. The design features a sharp-edged orifice that minimizes viscosity-related flow variations and incorporates Sun's floating style construction to reduce internal binding risks due to installation torque or machining discrepancies. An optional tuneable adjustment control allows for a 25% variation from the nominal preset flow via a simple three-turn adjust screw mechanism. The valve fits into a T-2A cavity and requires specific hex sizes for installation and adjustment purposes: a valve hex size of 1-1/8 inches (28.6 mm), an internal hex size for the adjustment screw of 5/32 inches (4 mm), and a locknut hex size of 9/16 inches (15 mm). This model weighs approximately .40 lb (0.20 kg) and comes with Viton seal options for enhanced durability.
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit.
- This valve is more highly damped than the FRDA to help solve system instability problems.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Both priority and bypass flow are usable up to the system operating pressure.
- Priority remains relatively constant regardless of variation in input flow.
- Bypass flow is not available until priority flow requirements are satisfied.
- Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 12 gpm45 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Input Flow | 30 gpm120 L/min. |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .40 lb0,20 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ