You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
FXAGXLN


$54.01 USD
  • SUN HYDRAULICS
  • Material:FXAGXLN
  • Model:FXAG-XLN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FXAGXLN (FXAGXLN) is a fixed-orifice, pressure-compensated flow control valve designed for precise flow regulation in meter-in or meter-out applications, even under conditions of wide pressure fluctuations. This valve offers a range of flow rates and features a sharp-edged orifice design that minimizes flow variations due to changes in viscosity. It is engineered for flush mounting, allowing it to be easily integrated into the surface of a manifold with a minimal footprint. The FXAGXLN can handle pressures up to 5000 psi (350 bar) at ports 1 and 2. The valve supports multiple flow rates: A Flow Rate at 2.0 in/min (32 cc/min), B Flow Rate at 2.5 in/min (40 cc/min), D and F Flow Rates at 3.0 in/min (48 cc/min), H and J Flow Rates at 4.0 in/min (64 cc/min), and L Flow Rate at 4.5 in/min (72 cc/min). It incorporates Sun's floating style construction, reducing the risk of internal parts binding due to excessive installation torque or machining variations within the cavity/cartridge. Designed for use with T8A cavities, the valve belongs to Series P and has a capacity of .5 gpm (2 L/min). The maximum operating pressure is set at 5000 psi (350 bar). Installation requires an internal hex size of 5/16 inch (8 mm) with an installation torque between 25-30 lbf-ft (35-40 Nm). A Viton seal kit is available for this cartridge model. This valve functions as a two-port restrictive flow control if the bypass port on a priority flow control is blocked. The compensating pressure is approximately 100 psi (7 bar), which provides adequate capacity while ensuring proper circuit operation.

Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. A variety of flow rates are available.

  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • Flush mount valves provide a small footprint. They can easily be mounted flush with the surface of the manifold.
  • Will accept 5000 psi (350 bar) at ports 1 and 2.
  • Flow Tolerances A Flow Rate +/- 2.0 in³/min. (+/- 32 cc/min.) B Flow Rate +/- 2.5 in³/min. (+/- 40 cc/min.) D and F Flow Rates +/- 3.0 in³/min. (+/- 48 cc/min.) H and J Flow Rates +/- 4.0 in³/min. (+/- 64 cc/min.) L Flow Rate +/- 4.5 in³/min. (+/- 72 cc/min.)
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-8A
Series P
Capacity .5 gpm2 L/min.
Maximum Operating Pressure 5000 psi350 bar
Valve Internal Hex Size 5/16 in.8 mm
Valve Installation Torque 25 - 30 lbf ft35 - 40 Nm
Seal kit - Cartridge Viton: 990-008-006

Show FAQ