***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics FXCAKAN (FXCAKAN) is a fixed orifice, pressure-compensated flow control valve designed for precise flow regulation in meter-in or meter-out applications, even amidst wide pressure fluctuations. This cartridge valve is factory-set to user-specified flow ratings with an accuracy of \u00b110% of the requested setting, and features a tunable control option allowing for a \u00b125% variation from the nominal preset flow. It incorporates EPDM seals suitable for phosphate ester fluid systems and is incompatible with petroleum-based fluids. The sharp-edged orifice design minimizes flow variations due to viscosity changes, ensuring consistent performance. The model's corrosion-resistant options are available with external stainless steel or zinc-nickel plated components. Physically and functionally interchangeable with other 2-port flow control cartridges of the same frame size, it fits into a T-13A cavity and has a capacity of 6 gpm (23 L/min) at a maximum operating pressure of 5000 psi (350 bar). The valve's construction minimizes internal binding risks due to excessive torque or machining variations. Installation requires specific torque settings: 30-35 lbf ft (41-47 Nm) for the valve installation, using a 7/8 in. hex size; an internal hex size of 5/32 in. (4 mm) is needed for adjustment screws; and locknuts require an additional torque setting of 80-90 lbf in. (9-10 Nm). Overall, this model weighs approximately .30 lb (.15 kg), making it lightweight yet robust for demanding environments.
The Sun Hydraulics FXCAKAN (FXCAKAN) is a fixed orifice, pressure-compensated flow control valve designed for precise flow regulation in meter-in or meter-out applications, even amidst wide pressure fluctuations. This cartridge valve is factory-set to user-specified flow ratings with an accuracy of \u00b110% of the requested setting, and features a tunable control option allowing for a \u00b125% variation from the nominal preset flow. It incorporates EPDM seals suitable for phosphate ester fluid systems and is incompatible with petroleum-based fluids. The sharp-edged orifice design minimizes flow variations due to viscosity changes, ensuring consistent performance. The model's corrosion-resistant options are available with external stainless steel or zinc-nickel plated components. Physically and functionally interchangeable with other 2-port flow control cartridges of the same frame size, it fits into a T-13A cavity and has a capacity of 6 gpm (23 L/min) at a maximum operating pressure of 5000 psi (350 bar). The valve's construction minimizes internal binding risks due to excessive torque or machining variations. Installation requires specific torque settings: 30-35 lbf ft (41-47 Nm) for the valve installation, using a 7/8 in. hex size; an internal hex size of 5/32 in. (4 mm) is needed for adjustment screws; and locknuts require an additional torque setting of 80-90 lbf in. (9-10 Nm). Overall, this model weighs approximately .30 lb (.15 kg), making it lightweight yet robust for demanding environments.
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at the factory.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
- Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
- All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-13A |
| Series | 1 |
| Capacity | 6 gpm23 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-010-006 |
Show FAQ