SUN HYDRAULICS
HDDALCV824
$191.41 USD
- SUN HYDRAULICS
- Material:HDDALCV824
- Model:HDDA-LCV@824
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics HDDALCV824 (HDDALCV824) is a solenoid-after check cartridge that combines a direct-acting solenoid poppet valve with a check function. This hybrid valve allows flow from the inlet port 2 to the system port 1, while blocking flow from port 2 to port 3 when the solenoid is de-energized. It is ideally suited for lift-lower applications and can be integrated directly into actuators, making it suitable for load-holding purposes. The solenoid tube assembly is fatigue-rated for service up to 5000 psi (350 bar), and the cartridge offers several manual override options, though manual override functionality is not compatible with weatherized coils. This valve incorporates a wet armature design, which allows working fluid to surround the armature and absorb heat generated by the coil. This feature necessitates consideration of fluid types as some, like water-glycol mixtures, may degrade over time at high temperatures. Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted in either direction on the tube. Additionally, coil connector options provide environmental protection ratings up to IP69K. The HDDALCV824 uses Sun's floating style construction to minimize binding issues due to installation torque or machining variations. It has a capacity of 10 gpm (40 L/min) and operates within a maximum pressure of 5000 psi (350 bar). The typical response time is around 50 milliseconds, with maximum valve leakage at specified conditions being minimal. The check cracking pressure stands at 30 psi (2 bar), and the valve supports high switching frequency up to 15000 cycles per hour. Installation requires specific torque settings and seal kits are available for maintenance needs.
The Sun Hydraulics HDDALCV824 (HDDALCV824) is a solenoid-after check cartridge that combines a direct-acting solenoid poppet valve with a check function. This hybrid valve allows flow from the inlet port 2 to the system port 1, while blocking flow from port 2 to port 3 when the solenoid is de-energized. It is ideally suited for lift-lower applications and can be integrated directly into actuators, making it suitable for load-holding purposes. The solenoid tube assembly is fatigue-rated for service up to 5000 psi (350 bar), and the cartridge offers several manual override options, though manual override functionality is not compatible with weatherized coils. This valve incorporates a wet armature design, which allows working fluid to surround the armature and absorb heat generated by the coil. This feature necessitates consideration of fluid types as some, like water-glycol mixtures, may degrade over time at high temperatures. Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted in either direction on the tube. Additionally, coil connector options provide environmental protection ratings up to IP69K. The HDDALCV824 uses Sun's floating style construction to minimize binding issues due to installation torque or machining variations. It has a capacity of 10 gpm (40 L/min) and operates within a maximum pressure of 5000 psi (350 bar). The typical response time is around 50 milliseconds, with maximum valve leakage at specified conditions being minimal. The check cracking pressure stands at 30 psi (2 bar), and the valve supports high switching frequency up to 15000 cycles per hour. Installation requires specific torque settings and seal kits are available for maintenance needs.
This solenoid-after check cartridge is a hybrid valve incorporating a direct acting solenoid poppet valve teed in after the check function. The check valve flow is from the inlet (port 2) to the system (port 1). With the solenoid de-energized flow from (port 2) to (port 3) is blocked. This combination valve is typically used in lift/lower applications and can be integrated directly into the actuator.
- The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
- This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is not compatible with weatherized coils.
- Suitable for load holding applications.
- This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
- Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted on the tube in either direction.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details. Additional weatherized coils and kits are available for more complete environmental protection.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 50 ms50 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi0,7 cc/min.@350 bar |
| Check Cracking Pressure | 30 psi2 bar |
| Switching Frequency | 15000 cycles/hr15000 cycles/hr |
| Manual Override Force Requirement | 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1 |
| Manual Override Stroke | .10 in.2,5 mm |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Seal kit - Cartridge | Viton: 990-011-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ