You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
NFCCLIN


$36.24 USD
  • SUN HYDRAULICS
  • Material:NFCCLIN
  • Model:NFCC-LIN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics NFCCLIN (Material Number: NFCCLIN) is a needle valve designed to provide precise flow regulation in hydraulic systems. It offers full adjustability from a closed position to the maximum orifice diameter, making it versatile for various applications requiring flow control or shutoff capabilities. This non-pressure compensated valve is interchangeable with other 2-port flow control cartridges, ensuring compatibility within the same frame size and cavity. The NFCCLIN features a balanced adjustment mechanism that facilitates easy adjustments even under high pressure conditions, and its sharp-edged orifice design minimizes flow variations due to changes in fluid viscosity. The valve supports bidirectional flow, with the preferred path being from port 1 to port 2 for easier interchangeability with other controls. When fully closed, it ensures zero leakage, providing reliable shutoff performance. The NFCCLIN model is built for high-pressure environments, with a maximum operating pressure of 5000 psi (350 bar). It can handle a capacity of 7 gpm (28 L/min) with an orifice diameter of .19 inch (4.8 mm). The adjustment mechanism allows for up to 5.5 counterclockwise turns from fully closed to fully open positions. Installation requires a torque of 30-35 lbf ft (41-47 Nm), and the valve weighs approximately .30 lb (.15 kg). Notably, this model can be configured with EPDM seals for use in systems utilizing phosphate ester fluids but should avoid petroleum-based fluids to prevent seal damage. The NFCCLIN is also compatible with Viton seal kits (Cartridge: 990010006) for enhanced durability and performance in various hydraulic applications.

Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff valves.

  • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
  • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • The flow path through this valve is bi-directional. The preferred path is port 1 to 2, to allow interchangeability with other flow controls.
  • There is no leakage when the adjustment mechanism is turned to the shut-off position.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.

CavityT-13A
Series1
Capacity7 gpm (.19 inch)28 L/min. (4,8 mm)
Maximum Operating Pressure5000 psi350 bar
Adjustment - Number of Counterclockwise Turns - Fully Closed to Fully Open55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.