SUN HYDRAULICS
PBDBJQN
$68.10 USD
- SUN HYDRAULICS
- Material:PBDBJQN
- Model:PBDB-JQN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBDBJQN (PBDBJQN) is a pilot-operated pressure reducing valve designed to maintain a consistent reduced pressure at port 1 from a higher primary pressure at inlet port 2. It supports circuits with multiple pressure requirements utilizing a single pump, making it versatile for various applications. The valve is part of the three-port pressure reducing and reducing-relieving cartridge family, which are physically interchangeable, sharing the same flow path and cavity for a given frame size. For optimal performance, especially in mounting configurations, using a full capacity return line port 3 with reducing-relieving cartridges is advisable. This valve is characterized by its very stable operation and low hysteresis due to its exceptionally flat pressure-flow characteristics. It features a main stage orifice protected by a 150-micron stainless steel screen and has specific maximum inlet pressures based on adjustment ranges: D, E, N, and Q ranges are tested up to 2000 psi; A, B, and H ranges up to 3000 psi; C and W ranges can handle up to 5000 psi. Pressure at port 3 adds directly to the valve setting in a 1:1 ratio but should not exceed 5000 psi. For applications requiring superior dynamic response, direct-acting valves are recommended over pilot-operated ones due to their faster action. The PBDBJQN also incorporates Sun's floating style construction to prevent internal parts binding due to excessive installation torque or machining variations. It has an installation torque range of 30-35 lbf ft (41-47 Nm) and features various adjustments for fine-tuning performance within its specified range. This model weighs approximately .30 lb (0.15 kg) and includes options for corrosion-resistant configurations with EPDM seals suitable for phosphate ester fluids.
The Sun Hydraulics PBDBJQN (PBDBJQN) is a pilot-operated pressure reducing valve designed to maintain a consistent reduced pressure at port 1 from a higher primary pressure at inlet port 2. It supports circuits with multiple pressure requirements utilizing a single pump, making it versatile for various applications. The valve is part of the three-port pressure reducing and reducing-relieving cartridge family, which are physically interchangeable, sharing the same flow path and cavity for a given frame size. For optimal performance, especially in mounting configurations, using a full capacity return line port 3 with reducing-relieving cartridges is advisable. This valve is characterized by its very stable operation and low hysteresis due to its exceptionally flat pressure-flow characteristics. It features a main stage orifice protected by a 150-micron stainless steel screen and has specific maximum inlet pressures based on adjustment ranges: D, E, N, and Q ranges are tested up to 2000 psi; A, B, and H ranges up to 3000 psi; C and W ranges can handle up to 5000 psi. Pressure at port 3 adds directly to the valve setting in a 1:1 ratio but should not exceed 5000 psi. For applications requiring superior dynamic response, direct-acting valves are recommended over pilot-operated ones due to their faster action. The PBDBJQN also incorporates Sun's floating style construction to prevent internal parts binding due to excessive installation torque or machining variations. It has an installation torque range of 30-35 lbf ft (41-47 Nm) and features various adjustments for fine-tuning performance within its specified range. This model weighs approximately .30 lb (0.15 kg) and includes options for corrosion-resistant configurations with EPDM seals suitable for phosphate ester fluids.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.