***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBDBKNV (PBDBKNV) is a pilot-operated pressure reducing valve designed to maintain a constant reduced pressure at port 1 by reducing a higher primary pressure from the inlet port 2. This functionality allows for circuits with varying pressure requirements to be efficiently managed using a single pump. The valve is part of a series where all three-port pressure reducing and reducing-relieving cartridges are physically interchangeable, sharing the same flow path and cavity for a given frame size. For certain mounting configurations, it's recommended to use a full capacity return line port 3 with reducing-relieving cartridges. Reverse flow from reduced pressure port 1 to inlet port 2 can cause the main spool to close, so incorporating a separate check valve may be necessary if reverse free flow is required. The main stage orifice is protected by a durable 150-micron stainless steel screen. The maximum inlet pressure varies by adjustment range, with ranges such as D, E, N, and Q tested up to 2000 psi differential and others like A, B, and H up to 3000 psi differential. Pilot-operated valves like this one are known for their stable performance and low hysteresis but are not fast-acting; direct-acting valves may be considered for applications requiring faster dynamic response. The PBDBKNV model incorporates Sun's floating style construction which minimizes internal binding risks due to excessive torque or machining variations. It has specific installation requirements including torque specifications and seal kit options for different fluid compatibilities. This model also supports corrosion-resistant configurations identified with specific suffixes in the model code for use in corrosive environments.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.