SUN HYDRAULICS
PBDBQEV


$83.99 USD
  • SUN HYDRAULICS
  • Material:PBDBQEV
  • Model:PBDB-QEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBDBQEV (PBDBQEV) is a sophisticated pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port, reducing them to a consistent pressure at the outlet. This valve is ideal for hydraulic circuits requiring multiple pressure levels from a single pump. It features three-port pressure reducing and relieving cartridges that are interchangeable, offering flexibility in various configurations. Notably, the main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability under different conditions. The maximum operating pressure of this valve is 5000 psi (350 bar), with specific ranges tested for maximum differential pressures: 2000 psi for D, E, N, and Q ranges, and 3000 psi for A, B, and H ranges. This product exhibits exceptionally stable pressure-flow characteristics with low hysteresis due to its pilot-operated design. However, it is not fast-acting; for applications requiring rapid response times, direct-acting valves are recommended instead. The PBDBQEV incorporates Sun's floating style construction to minimize internal part binding due to installation torque or machining variations. Additionally, it includes corrosion-resistant options identified by model code suffixes AP or LH for environments prone to corrosion. For optimal performance in circuits requiring reverse free flow from the reduced pressure port to the inlet port, consider adding a separate check valve as reverse flow can cause the main spool to close. The valve's design allows adjustments via an internal hex screw and locknut system with specified torque values ensuring secure settings. This model also accommodates EPDM seals suitable for systems using phosphate ester fluids but should avoid petroleum-based substances that could damage these seals.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.