SUN HYDRAULICS
PBDBWNV
$85.98 USD
- SUN HYDRAULICS
- Material:PBDBWNV
- Model:PBDB-WNV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBDBWNV (PBDBWNV) is a pilot-operated pressure reducing valve designed to manage high primary pressures by reducing them to a consistent lower pressure, enabling circuits with diverse pressure needs to function with a single pump. This three-port valve is interchangeable with other pressure reducing and relieving cartridges of the same frame size, making it versatile for various configurations. It features a stainless steel screen protecting the main stage orifice and operates with exceptionally flat pressure-flow characteristics, offering stability and low hysteresis. The valve's maximum inlet pressure varies by range, supporting up to 5000 psi (350 bar) for certain configurations. It incorporates Sun's floating style construction, mitigating internal binding risks due to installation torque or machining variations. The PBDBWNV can handle reverse flow from reduced pressure port 1 to inlet port 2 but may require an additional check valve if free reverse flow is needed. It's important to note that this model is not fast-acting; for improved dynamic response, direct-acting valves are recommended. EPDM seal options are available for systems using phosphate ester fluids, while corrosion-resistant variants are identified by specific model code suffixes like AP or LH. This cartridge valve fits into a T-11A cavity and has a capacity of 10 gpm (40 L/min), with factory settings established at blocked control ports. The adjustment mechanism allows for fine-tuning within its full range using W or Y control options, unless a special setting limits the maximum adjustment. Installation requires specific torque settings and hex sizes for secure fitting, ensuring reliable performance across its applications in hydraulic systems requiring precise pressure regulation.
The Sun Hydraulics PBDBWNV (PBDBWNV) is a pilot-operated pressure reducing valve designed to manage high primary pressures by reducing them to a consistent lower pressure, enabling circuits with diverse pressure needs to function with a single pump. This three-port valve is interchangeable with other pressure reducing and relieving cartridges of the same frame size, making it versatile for various configurations. It features a stainless steel screen protecting the main stage orifice and operates with exceptionally flat pressure-flow characteristics, offering stability and low hysteresis. The valve's maximum inlet pressure varies by range, supporting up to 5000 psi (350 bar) for certain configurations. It incorporates Sun's floating style construction, mitigating internal binding risks due to installation torque or machining variations. The PBDBWNV can handle reverse flow from reduced pressure port 1 to inlet port 2 but may require an additional check valve if free reverse flow is needed. It's important to note that this model is not fast-acting; for improved dynamic response, direct-acting valves are recommended. EPDM seal options are available for systems using phosphate ester fluids, while corrosion-resistant variants are identified by specific model code suffixes like AP or LH. This cartridge valve fits into a T-11A cavity and has a capacity of 10 gpm (40 L/min), with factory settings established at blocked control ports. The adjustment mechanism allows for fine-tuning within its full range using W or Y control options, unless a special setting limits the maximum adjustment. Installation requires specific torque settings and hex sizes for secure fitting, ensuring reliable performance across its applications in hydraulic systems requiring precise pressure regulation.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.