SUN HYDRAULICS
PBDFWPV
$84.98 USD
- SUN HYDRAULICS
- Material:PBDFWPV
- Model:PBDF-WPV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBDFWPV (Material Number: PBDFWPV) is a pilot-operated pressure reducing valve designed to reduce high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, facilitating operations of circuits with multiple pressure requirements using a single pump. The main stage orifice is drilled into the piston, enhancing durability in demanding applications. It allows full reverse flow from reduced pressure port 1 to inlet port 2, although this may lead to the main spool closing. For circuits requiring reverse free flow, it is advisable to integrate a separate check valve. If pilot flow consumption is critical, direct-acting reducing-relieving valves are recommended. The maximum inlet pressure varies with the adjustment range: D, E, N, and Q ranges are tested with a 2000 psi maximum differential; A, B, and H with 3000 psi; and C and W with 5000 psi of inlet pressure. This pilot-operated valve features exceptionally flat pressure-flow characteristics with low hysteresis and high stability. Pressure at port 3 adds directly to the valve setting at a 1:1 ratio but should not exceed 5000 psi. Although not fast-acting by nature, for superior dynamic response direct-acting valves are suggested. The W and Y controls can be specified with or without special settings; without special settings, they are adjustable throughout their full range. All three-port cartridges are physically interchangeable across given frame sizes for flexibility in mounting configurations. Corrosion-resistant variants are available for use in corrosive environments identified by model code suffixes AP or LH for stainless steel or zinc-nickel plated components respectively. The floating style construction minimizes binding risks due to excessive torque or machining variations during installation.
The Sun Hydraulics PBDFWPV (Material Number: PBDFWPV) is a pilot-operated pressure reducing valve designed to reduce high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, facilitating operations of circuits with multiple pressure requirements using a single pump. The main stage orifice is drilled into the piston, enhancing durability in demanding applications. It allows full reverse flow from reduced pressure port 1 to inlet port 2, although this may lead to the main spool closing. For circuits requiring reverse free flow, it is advisable to integrate a separate check valve. If pilot flow consumption is critical, direct-acting reducing-relieving valves are recommended. The maximum inlet pressure varies with the adjustment range: D, E, N, and Q ranges are tested with a 2000 psi maximum differential; A, B, and H with 3000 psi; and C and W with 5000 psi of inlet pressure. This pilot-operated valve features exceptionally flat pressure-flow characteristics with low hysteresis and high stability. Pressure at port 3 adds directly to the valve setting at a 1:1 ratio but should not exceed 5000 psi. Although not fast-acting by nature, for superior dynamic response direct-acting valves are suggested. The W and Y controls can be specified with or without special settings; without special settings, they are adjustable throughout their full range. All three-port cartridges are physically interchangeable across given frame sizes for flexibility in mounting configurations. Corrosion-resistant variants are available for use in corrosive environments identified by model code suffixes AP or LH for stainless steel or zinc-nickel plated components respectively. The floating style construction minimizes binding risks due to excessive torque or machining variations during installation.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.