You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PBFBFHN


$103.35 USD
  • SUN HYDRAULICS
  • Material:PBFBFHN
  • Model:PBFB-FHN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFBFHN (PBFBFHN) is a pilot-operated pressure reducing valve designed to reduce high primary pressure at inlet port 2 to a consistent, reduced pressure at port 1. This allows circuits with varying pressure requirements to operate efficiently using a single pump. The valve is physically interchangeable with other three-port pressure reducing and reducing-relieving cartridges, maintaining the same flow path and cavity for a given frame size. It is recommended that a full capacity return line port 3 be utilized with reducing-relieving cartridges to optimize performance. The valve features a main stage orifice protected by a 150-micron stainless steel screen, ensuring durability and reliability under various conditions. The PBFBFHN model can handle maximum operating pressures of up to 5000 psi (350 bar), with specific adjustment ranges tested for different maximum differentials between inlet and reduced pressures: Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) differential, while Ranges A, B, and H are tested with a 3000 psi (210 bar) differential. The valve exhibits stable performance with low hysteresis due to its exceptionally flat pressure-flow characteristics. It incorporates Sun's floating style construction to minimize internal binding risks due to excessive installation torque or machining variations. This model can be adjusted throughout its full range using W or Y control options unless specified otherwise for special settings. Cartridges configured with EPDM seals are suitable for systems utilizing phosphate ester fluids but should not be exposed to petroleum-based fluids. The PBFBFHN is an ideal choice when precise pressure regulation is required in hydraulic systems while maintaining ease of adjustability and stability under varying operational demands.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.