SUN HYDRAULICS
PBFBWCN
$113.28 USD
- SUN HYDRAULICS
- Material:PBFBWCN
- Model:PBFB-WCN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFBWCN (Material Number: PBFBWCN) is a pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port, reducing them to a consistent lower pressure at port 1. This functionality is ideal for circuits requiring multiple pressure settings from a single pump. The valve's three-port configuration allows for physical interchangeability, maintaining the same flow path and cavity size across similar frame sizes. It is recommended to utilize a full-capacity return line port 3 with reducing-relieving cartridges for optimal performance. While the main spool may close during full reverse flow from reduced pressure port 1 to inlet port 2, incorporating a separate check valve can address this issue if reverse free flow is necessary. The valve features a stainless steel screen protecting the main stage orifice and supports maximum inlet pressures based on specific adjustment ranges: D, E, N, and Q ranges are tested with up to 2000 psi differential, while A, B, and H ranges handle up to 3000 psi differential. The C and W ranges can withstand an impressive 5000 psi of inlet pressure. Known for its stable performance and low hysteresis, this pilot-operated valve offers exceptionally flat pressure-flow characteristics. While not inherently fast-acting, it provides superior stability in applications that do not demand rapid dynamic response\u2014though direct-acting valves are suggested for such needs. The PBFBWCN includes Sun's floating style construction to minimize internal binding risks due to excessive installation torque or machining variations. It has an installation torque of 45-50 lbf ft and requires specific adjustments using an internal hex screw. Additionally, cartridges with EPDM seals are suitable for systems using phosphate ester fluids but should avoid petroleum-based fluids to prevent seal damage.
The Sun Hydraulics PBFBWCN (Material Number: PBFBWCN) is a pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port, reducing them to a consistent lower pressure at port 1. This functionality is ideal for circuits requiring multiple pressure settings from a single pump. The valve's three-port configuration allows for physical interchangeability, maintaining the same flow path and cavity size across similar frame sizes. It is recommended to utilize a full-capacity return line port 3 with reducing-relieving cartridges for optimal performance. While the main spool may close during full reverse flow from reduced pressure port 1 to inlet port 2, incorporating a separate check valve can address this issue if reverse free flow is necessary. The valve features a stainless steel screen protecting the main stage orifice and supports maximum inlet pressures based on specific adjustment ranges: D, E, N, and Q ranges are tested with up to 2000 psi differential, while A, B, and H ranges handle up to 3000 psi differential. The C and W ranges can withstand an impressive 5000 psi of inlet pressure. Known for its stable performance and low hysteresis, this pilot-operated valve offers exceptionally flat pressure-flow characteristics. While not inherently fast-acting, it provides superior stability in applications that do not demand rapid dynamic response\u2014though direct-acting valves are suggested for such needs. The PBFBWCN includes Sun's floating style construction to minimize internal binding risks due to excessive installation torque or machining variations. It has an installation torque of 45-50 lbf ft and requires specific adjustments using an internal hex screw. Additionally, cartridges with EPDM seals are suitable for systems using phosphate ester fluids but should avoid petroleum-based fluids to prevent seal damage.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.