***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFBWEV (PBFBWEV) is a pilot-operated pressure reducing valve designed to manage high primary pressure at inlet port 2 and maintain a consistent reduced pressure at port 1. This allows for efficient operation of circuits requiring multiple pressure levels using just one pump. The valve is interchangeable with other three-port pressure reducing and reducing-relieving cartridges, sharing the same flow path and cavity for a given frame size. It is recommended to use a full capacity return line port 3 with reducing-relieving cartridges for optimal performance. The main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability under maximum operating pressures up to 5000 psi (350 bar), depending on the adjustment range selected. The PBFBWEV exhibits stable, low hysteresis characteristics, making it suitable for applications where precise pressure control is essential. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. Cartridges with EPDM seals are compatible with phosphate ester fluids but should not be exposed to petroleum-based fluids. For superior dynamic response in applications requiring fast-acting valves, direct-acting valves are recommended over pilot-operated ones like the PBFBWEV. Additionally, if reverse free flow from reduced pressure port 1 to inlet port 2 is needed in your circuit, consider integrating a separate check valve as the main spool may close under such conditions. The valve's adjustability allows for fine-tuning across its full range using W or Y controls, unless specified otherwise with a special setting indicating the maximum setting of the valve.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg