SUN HYDRAULICS
PBFBWWN
$110.30 USD
- SUN HYDRAULICS
- Material:PBFBWWN
- Model:PBFB-WWN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFBWWN (Material Number: PBFBWWN) is a pilot-operated pressure reducing valve designed to reduce a high primary pressure at the inlet port 2 to a constant, reduced pressure at port 1. This allows circuits with varying pressure requirements to be efficiently operated using a single pump. The valve features interchangeable three-port pressure reducing and reducing-relieving cartridges, making it adaptable for different configurations. It is recommended that the full capacity return line port 3 be utilized with reducing-relieving cartridges for optimal performance. The PBFBWWN model can handle full reverse flow from reduced pressure port 1 to inlet port 2, though this may cause the main spool to close. For applications requiring reverse free flow, adding a separate check valve is advisable. This valve includes a main stage orifice protected by a 150-micron stainless steel screen and supports maximum inlet pressures based on adjustment ranges\u2014up to 5000 psi (350 bar) for certain configurations. Known for its stable and low hysteresis characteristics, the pilot-operated design offers flat pressure-flow characteristics but is not intended for fast-acting applications; direct-acting valves are suggested where superior dynamic response is needed. The cartridge incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. Additional specifications include a capacity of 20 gpm (80 L/min), maximum operating pressure of 5000 psi (350 bar), and control pilot flow between 10 - 15 in\u00b3/min (0.16 - 0.25 L/min). The valve features an adjustable screw with an internal hex size of 5/32 inches and requires specific installation torques for optimal operation. The model's weight is approximately .60 lb (0.30 kg), and it comes equipped with Viton seals suitable for systems utilizing phosphate ester fluids while being incompatible with petroleum-based substances.
The Sun Hydraulics PBFBWWN (Material Number: PBFBWWN) is a pilot-operated pressure reducing valve designed to reduce a high primary pressure at the inlet port 2 to a constant, reduced pressure at port 1. This allows circuits with varying pressure requirements to be efficiently operated using a single pump. The valve features interchangeable three-port pressure reducing and reducing-relieving cartridges, making it adaptable for different configurations. It is recommended that the full capacity return line port 3 be utilized with reducing-relieving cartridges for optimal performance. The PBFBWWN model can handle full reverse flow from reduced pressure port 1 to inlet port 2, though this may cause the main spool to close. For applications requiring reverse free flow, adding a separate check valve is advisable. This valve includes a main stage orifice protected by a 150-micron stainless steel screen and supports maximum inlet pressures based on adjustment ranges\u2014up to 5000 psi (350 bar) for certain configurations. Known for its stable and low hysteresis characteristics, the pilot-operated design offers flat pressure-flow characteristics but is not intended for fast-acting applications; direct-acting valves are suggested where superior dynamic response is needed. The cartridge incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. Additional specifications include a capacity of 20 gpm (80 L/min), maximum operating pressure of 5000 psi (350 bar), and control pilot flow between 10 - 15 in\u00b3/min (0.16 - 0.25 L/min). The valve features an adjustable screw with an internal hex size of 5/32 inches and requires specific installation torques for optimal operation. The model's weight is approximately .60 lb (0.30 kg), and it comes equipped with Viton seals suitable for systems utilizing phosphate ester fluids while being incompatible with petroleum-based substances.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.