SUN HYDRAULICS
PBFFCBN
$110.30 USD
- SUN HYDRAULICS
- Material:PBFFCBN
- Model:PBFF-CBN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFFCBN (Material Number: PBFFCBN) is a pilot-operated pressure reducing valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1. This feature allows circuits with multiple pressure requirements to be operated using a single pump. The valve's main stage orifice is drilled directly into the piston, enhancing durability and making it suitable for demanding applications. It offers physical interchangeability across three-port pressure reducing and reducing-relieving cartridges, ensuring compatibility in terms of flow path and cavity within the same frame size. For optimal performance, particularly when using reducing-relieving cartridges, it is recommended to employ a full-capacity return line at port 3. The valve supports full reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close, necessitating an additional check valve if reverse free flow is required. Pilot-operated valves like the PBFFCBN exhibit low hysteresis and stable pressure-flow characteristics but are not fast-acting; for superior dynamic response, direct-acting valves are suggested. The maximum inlet pressure varies by adjustment range: D, E, N, and Q ranges accommodate up to 2000 psi differential; A, B, and H ranges handle up to 3000 psi; while C and W ranges manage up to 5000 psi. Pressure at port 3 should not exceed 5000 psi as it directly adds to the valve setting in a 1:1 ratio. This model incorporates Sun's floating style construction which minimizes internal part binding due to installation torque or machining variations. It features specific installation parameters including a cavity type T-2A series with a capacity of 20 gpm (80 L/min) and comes with an optional polyurethane seal kit (990002002).
The Sun Hydraulics PBFFCBN (Material Number: PBFFCBN) is a pilot-operated pressure reducing valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1. This feature allows circuits with multiple pressure requirements to be operated using a single pump. The valve's main stage orifice is drilled directly into the piston, enhancing durability and making it suitable for demanding applications. It offers physical interchangeability across three-port pressure reducing and reducing-relieving cartridges, ensuring compatibility in terms of flow path and cavity within the same frame size. For optimal performance, particularly when using reducing-relieving cartridges, it is recommended to employ a full-capacity return line at port 3. The valve supports full reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close, necessitating an additional check valve if reverse free flow is required. Pilot-operated valves like the PBFFCBN exhibit low hysteresis and stable pressure-flow characteristics but are not fast-acting; for superior dynamic response, direct-acting valves are suggested. The maximum inlet pressure varies by adjustment range: D, E, N, and Q ranges accommodate up to 2000 psi differential; A, B, and H ranges handle up to 3000 psi; while C and W ranges manage up to 5000 psi. Pressure at port 3 should not exceed 5000 psi as it directly adds to the valve setting in a 1:1 ratio. This model incorporates Sun's floating style construction which minimizes internal part binding due to installation torque or machining variations. It features specific installation parameters including a cavity type T-2A series with a capacity of 20 gpm (80 L/min) and comes with an optional polyurethane seal kit (990002002).
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Polyurethane: 990-002-002 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.