SUN HYDRAULICS
PBFFCCV


$121.22 USD
  • SUN HYDRAULICS
  • Material:PBFFCCV
  • Model:PBFF-CCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFFCCV (Material Number: PBFFCCV) is a pilot-operated pressure reducing valve designed to manage high primary pressure at the inlet port 2, reducing it to a constant lower pressure at port 1. This capability allows for the operation of circuits with varying pressure requirements using a single pump. The valve features a main stage orifice drilled into the piston, enhancing its durability for demanding applications. It is compatible with all three-port pressure reducing and reducing-relieving cartridges, allowing for physical interchangeability across similar frame sizes. For optimal performance in certain mounting configurations, utilizing a full capacity return line port 3 with reducing-relieving cartridges is recommended. This model supports full reverse flow from reduced pressure port 1 to inlet port 2, which may close the main spool; hence, incorporating a separate check valve is advisable if reverse free flow is necessary. The PBFFCCV demonstrates exceptionally flat pressure-flow characteristics, stability, and low hysteresis due to its pilot-operated nature. It incorporates Sun's floating style construction to minimize internal binding risks due to excessive installation torque or machining variations. The valve's maximum inlet pressure depends on the adjustment range: Ranges D, E, N, and Q accommodate up to 2000 psi differential; Ranges A, B, and H up to 3000 psi; and Ranges C and W up to 5000 psi. Additionally, the valve setting at port 3 should not exceed 5000 psi as it directly adds to the valve setting in a 1:1 ratio. While pilot-operated valves are not fast-acting compared to direct-acting valves, they offer moderate speed with easy adjustability for various applications requiring stable pressure regulation.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgePolyurethane: 990-002-002

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.