SUN HYDRAULICS
PBFFKCN
$119.24 USD
- SUN HYDRAULICS
- Material:PBFFKCN
- Model:PBFF-KCN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFFKCN (PBFFKCN) is a pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port, ensuring a consistent reduced pressure at port 1. This valve is particularly beneficial for systems requiring multiple pressure levels operated by a single pump. It features a main stage orifice drilled into the piston, enhancing its durability in demanding applications. The PBFFKCN model is compatible with all three-port pressure reducing and reducing-relieving cartridges, allowing for interchangeable use within the same frame size and flow path. When using reducing-relieving cartridges, it is advised to utilize a full-capacity return line port 3 for optimal performance. This valve supports reverse flow from the reduced pressure port 1 to inlet port 2, although this may cause the main spool to close. For circuits needing reverse free flow, integrating a separate check valve is recommended. The PBFFKCN operates with exceptionally flat pressure-flow characteristics and boasts high stability with low hysteresis. It is suited for applications where pilot flow consumption is not critical; otherwise, direct-acting valves should be considered. The recommended maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q have a maximum differential of 2000 psi; ranges A, B, and H allow up to 3000 psi; and ranges C and W can handle up to 5000 psi of inlet pressure. The valve's construction minimizes internal part binding due to excessive installation torque or machining variations. With a capacity of 20 gpm (80 L/min), this model offers reliable performance in hydraulic systems requiring precise pressure control.
The Sun Hydraulics PBFFKCN (PBFFKCN) is a pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port, ensuring a consistent reduced pressure at port 1. This valve is particularly beneficial for systems requiring multiple pressure levels operated by a single pump. It features a main stage orifice drilled into the piston, enhancing its durability in demanding applications. The PBFFKCN model is compatible with all three-port pressure reducing and reducing-relieving cartridges, allowing for interchangeable use within the same frame size and flow path. When using reducing-relieving cartridges, it is advised to utilize a full-capacity return line port 3 for optimal performance. This valve supports reverse flow from the reduced pressure port 1 to inlet port 2, although this may cause the main spool to close. For circuits needing reverse free flow, integrating a separate check valve is recommended. The PBFFKCN operates with exceptionally flat pressure-flow characteristics and boasts high stability with low hysteresis. It is suited for applications where pilot flow consumption is not critical; otherwise, direct-acting valves should be considered. The recommended maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q have a maximum differential of 2000 psi; ranges A, B, and H allow up to 3000 psi; and ranges C and W can handle up to 5000 psi of inlet pressure. The valve's construction minimizes internal part binding due to excessive installation torque or machining variations. With a capacity of 20 gpm (80 L/min), this model offers reliable performance in hydraulic systems requiring precise pressure control.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Polyurethane: 990-002-002 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.