***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFFOBN (Material Number: PBFFOBN) is a pilot-operated, pressure-reducing valve designed to manage high primary pressure at inlet port 2, reducing it to a consistent lower pressure at port 1. This functionality is essential for systems requiring multiple pressure levels from a single pump. The valve features a main stage orifice drilled into the piston, enhancing its durability for demanding applications. It is part of a series where all three-port pressure reducing and reducing-relieving cartridges are interchangeable, sharing the same flow path and cavity for equivalent frame sizes. For optimal performance in certain mounting configurations, it is recommended that a full capacity return line at port 3 be utilized with reducing-relieving cartridges. The Sun Hydraulics PBFFOBN can handle full reverse flow from reduced pressure port 1 to inlet port 2, although this may cause the main spool to close. In circuits requiring reverse free flow, incorporating a separate check valve is advisable. When pilot flow consumption is critical, direct-acting reducing-relieving valves might be more suitable due to their faster response compared to pilot-operated valves like the PBFFOBN. This valve exhibits stable performance with low hysteresis and exceptionally flat pressure-flow characteristics. The maximum recommended inlet pressure varies by adjustment range: D, E, N, and Q ranges are tested up to 2000 psi (140 bar) differential; A, B, and H ranges up to 3000 psi (210 bar); C and W ranges can handle up to 5000 psi (350 bar). Pressure at port 3 directly affects the valve setting in a 1:1 ratio and should not exceed 5000 psi (350 bar). The PBFFOBN incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations.
The Sun Hydraulics PBFFOBN (Material Number: PBFFOBN) is a pilot-operated, pressure-reducing valve designed to manage high primary pressure at inlet port 2, reducing it to a consistent lower pressure at port 1. This functionality is essential for systems requiring multiple pressure levels from a single pump. The valve features a main stage orifice drilled into the piston, enhancing its durability for demanding applications. It is part of a series where all three-port pressure reducing and reducing-relieving cartridges are interchangeable, sharing the same flow path and cavity for equivalent frame sizes. For optimal performance in certain mounting configurations, it is recommended that a full capacity return line at port 3 be utilized with reducing-relieving cartridges. The Sun Hydraulics PBFFOBN can handle full reverse flow from reduced pressure port 1 to inlet port 2, although this may cause the main spool to close. In circuits requiring reverse free flow, incorporating a separate check valve is advisable. When pilot flow consumption is critical, direct-acting reducing-relieving valves might be more suitable due to their faster response compared to pilot-operated valves like the PBFFOBN. This valve exhibits stable performance with low hysteresis and exceptionally flat pressure-flow characteristics. The maximum recommended inlet pressure varies by adjustment range: D, E, N, and Q ranges are tested up to 2000 psi (140 bar) differential; A, B, and H ranges up to 3000 psi (210 bar); C and W ranges can handle up to 5000 psi (350 bar). Pressure at port 3 directly affects the valve setting in a 1:1 ratio and should not exceed 5000 psi (350 bar). The PBFFOBN incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Polyurethane: 990-002-002 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.