You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PBFFOWN


$118.24 USD
  • SUN HYDRAULICS
  • Material:PBFFOWN
  • Model:PBFF-OWN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFFOWN (Material Number: PBFFOWN) is a pilot-operated pressure reducing valve designed to regulate high primary pressure at inlet port 2 to a constant, reduced pressure at port 1. This feature allows for the operation of circuits with multiple pressure requirements using a single pump. The valve's design includes the main stage orifice drilled into the piston, enhancing its durability in physically demanding applications. It is compatible with three-port pressure reducing and reducing-relieving cartridges, allowing physical interchangeability due to identical flow paths and cavity sizes for a given frame size. For optimal performance, especially when using reducing-relieving cartridges, it is advised to utilize a full capacity return line at port 3. The PBFFOWN model supports reverse flow from reduced pressure port 1 to inlet port 2, but this may cause the main spool to close; thus, incorporating a separate check valve in circuits requiring reverse free flow is recommended. In terms of pilot flow consumption, direct-acting reducing-relieving valves are suggested if critical. The maximum recommended inlet pressure depends on the adjustment range: Ranges D, E, N, and Q handle up to 2000 psi differential; Ranges A, B, and H manage up to 3000 psi; while Ranges C and W accommodate up to 5000 psi. This valve type exhibits low hysteresis and stable performance with exceptionally flat pressure-flow characteristics but is not fast-acting compared to direct-acting valves. Its construction incorporates Sun's floating style design that minimizes internal part binding due to excessive installation torque or cavity/cartridge machining variations. Additional specifications include a capacity of 20 gpm (80 L/min), factory pressure settings established at blocked control ports dead-headed, and various torque requirements for installation and adjustments.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgePolyurethane: 990-002-002

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.