You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PBHBQQN


$225.87 USD
  • SUN HYDRAULICS
  • Material:PBHBQQN
  • Model:PBHB-QQN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHBQQN (PBHBQQN) is a pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port and reduce them to a consistent lower pressure at port 1. This functionality allows for the operation of circuits with varying pressure requirements using a single pump. The valve is physically interchangeable with other three-port pressure reducing and reducing-relieving cartridges, sharing the same flow path and cavity for a given frame size. It is recommended to use a full capacity return line at port 3 when employing reducing-relieving cartridges to ensure optimal performance. If reverse free flow is needed in the circuit, incorporating a separate check valve may be advisable. The valve exhibits stable pressure-flow characteristics with low hysteresis, making it suitable for applications requiring precise pressure control. It operates best within specified maximum inlet pressures determined by its adjustment range, with different ranges tested under varying maximum differentials between inlet and reduced pressures. The PBHBQQN model incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations, enhancing reliability. It features an adjustment capability of up to 5.5 clockwise turns to increase settings and can handle a maximum operating pressure of 5000 psi (350 bar). The valve's design includes specific considerations for pilot flow consumption; if this is critical, direct-acting valves might be preferred due to their faster response times. Additionally, the cartridge can be configured with EPDM seals for use in systems utilizing phosphate ester fluids, although exposure to petroleum-based fluids should be avoided as it could damage the seals. This product's versatility makes it an effective solution for hydraulic systems requiring multi-pressure operations with robust stability and precision control capabilities.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg
Seal kit - CartridgeViton: 990-017-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure