SUN HYDRAULICS
PBHBYHV


$253.66 USD
  • SUN HYDRAULICS
  • Material:PBHBYHV
  • Model:PBHB-YHV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHBYHV (PBHBYHV) is a pilot-operated pressure reducing valve designed to regulate high primary pressure at inlet port 2, ensuring a consistent reduced pressure at port 1. This functionality allows for the efficient operation of circuits with varying pressure requirements using a single pump. The valve is part of the three-port pressure reducing and reducing-relieving cartridge family, offering physical interchangeability across similar frame sizes. It is recommended to utilize a full capacity return line port 3 when using reducing-relieving cartridges to optimize performance. In cases where reverse free flow from reduced pressure port 1 to inlet port 2 is necessary, integrating a separate check valve into the circuit is advisable. The maximum recommended inlet pressure varies by adjustment range: ranges D, E, N, and Q support up to 2000 psi (140 bar), while ranges A, B, and H accommodate up to 3000 psi (210 bar), and ranges C and W handle up to 5000 psi (350 bar). This valve features exceptionally flat pressure-flow characteristics with low hysteresis and stability. The pressure at port 3 directly adds to the valve setting at a 1:1 ratio but should not exceed 5000 psi (350 bar). While pilot-operated valves are not fast-acting, they offer ease of adjustment over their full range when specified without special settings. For applications requiring superior dynamic response or critical pilot flow consumption considerations, direct-acting valves are recommended. The PBHBYHV incorporates Sun's floating style construction to minimize potential internal binding due to installation torque or machining variations. It has a capacity of up to 40 gpm (160 L/min) with factory settings established at blocked control ports and can operate under pressures up to 5000 psi (350 bar).

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg
Seal kit - CartridgeViton: 990-017-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure