You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PBHFKAN


$223.88 USD
  • SUN HYDRAULICS
  • Material:PBHFKAN
  • Model:PBHF-KAN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHFKAN (PBHFKAN) is a pilot-operated pressure reducing valve designed to maintain a constant reduced pressure at port 1 while handling high primary pressures at the inlet port 2. This valve is ideal for circuits requiring multiple pressure settings from a single pump. Its construction includes a main stage orifice drilled directly into the piston, enhancing its durability in demanding applications. The valve's three-port design allows for physical interchangeability among reducing and reducing-relieving cartridges of the same frame size, making it versatile for various mounting configurations. It is recommended to use a full capacity return line port 3 with reducing-relieving cartridges to ensure optimal performance. For circuits requiring reverse free flow from reduced pressure port 1 to inlet port 2, incorporating an additional check valve is advisable. The PBHFKAN supports maximum inlet pressures based on different adjustment ranges: Ranges D, E, N, and Q accommodate up to a 2000 psi differential, while Ranges A, B, and H handle up to 3000 psi. Ranges C and W can withstand an inlet pressure of up to 5000 psi. This pilot-operated valve exhibits stable pressure-flow characteristics with low hysteresis but is not intended for fast-acting applications; direct-acting valves are recommended for superior dynamic response. Featuring Sun's floating style construction, the PBHFKAN minimizes potential binding of internal parts due to excessive installation torque or machining variations. The valve has a capacity of 40 gpm (160 L/min), with factory pressure settings established at blocked control ports. It operates efficiently within its specified torque and adjustment parameters, ensuring reliable performance across various hydraulic systems.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg
Seal kit - CartridgeViton: 990-017-006

Show FAQ