***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHFMEN (Material Number: PBHFMEN) is a pilot-operated, pressure-reducing valve designed to lower high primary pressure at inlet port 2 to a consistent reduced pressure at port 1. This feature allows for the operation of circuits with varying pressure requirements using a single pump. The valve's main stage orifice is drilled into the piston, enhancing its durability for physically demanding applications. It is interchangeable with other three-port pressure-reducing and reducing-relieving cartridges of the same frame size, providing flexibility in flow path and cavity configuration. For mounting configurations, it may be recommended to use a full-capacity return line at port 3 with reducing-relieving cartridges. The valve allows full reverse flow from the reduced pressure port 1 to inlet port 2, which may cause the main spool to close. To ensure reverse free flow in such circuits, adding a separate check valve is advisable. When pilot flow consumption is critical, direct-acting reducing-relieving valves are a better choice due to their faster response times. The maximum inlet pressure varies by adjustment range: Ranges D, E, N, and Q accommodate up to a 2000 psi differential; Ranges A, B, and H handle up to 3000 psi; and Ranges C and W support up to 5000 psi. This valve exhibits stable performance with low hysteresis due to its exceptionally flat pressure-flow characteristics. Pressure at port 3 adds directly to the valve setting at a 1:1 ratio but should not exceed 5000 psi. The design incorporates Sun's floating style construction to minimize internal binding risks due to excessive torque or machining variations during installation. With a capacity of 40 gpm and operating pressures up to 5000 psi, this versatile valve suits various hydraulic applications requiring precise pressure control.
The Sun Hydraulics PBHFMEN (Material Number: PBHFMEN) is a pilot-operated, pressure-reducing valve designed to lower high primary pressure at inlet port 2 to a consistent reduced pressure at port 1. This feature allows for the operation of circuits with varying pressure requirements using a single pump. The valve's main stage orifice is drilled into the piston, enhancing its durability for physically demanding applications. It is interchangeable with other three-port pressure-reducing and reducing-relieving cartridges of the same frame size, providing flexibility in flow path and cavity configuration. For mounting configurations, it may be recommended to use a full-capacity return line at port 3 with reducing-relieving cartridges. The valve allows full reverse flow from the reduced pressure port 1 to inlet port 2, which may cause the main spool to close. To ensure reverse free flow in such circuits, adding a separate check valve is advisable. When pilot flow consumption is critical, direct-acting reducing-relieving valves are a better choice due to their faster response times. The maximum inlet pressure varies by adjustment range: Ranges D, E, N, and Q accommodate up to a 2000 psi differential; Ranges A, B, and H handle up to 3000 psi; and Ranges C and W support up to 5000 psi. This valve exhibits stable performance with low hysteresis due to its exceptionally flat pressure-flow characteristics. Pressure at port 3 adds directly to the valve setting at a 1:1 ratio but should not exceed 5000 psi. The design incorporates Sun's floating style construction to minimize internal binding risks due to excessive torque or machining variations during installation. With a capacity of 40 gpm and operating pressures up to 5000 psi, this versatile valve suits various hydraulic applications requiring precise pressure control.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 40 gpm160 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.30 lb0,60 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction