SUN HYDRAULICS
PBHFQQV
$225.87 USD
- SUN HYDRAULICS
- Material:PBHFQQV
- Model:PBHF-QQV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHFQQV (PBHFQQV) is a pilot-operated pressure reducing valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1. This feature allows circuits with multiple pressure requirements to be operated using a single pump, making it an efficient choice for various hydraulic applications. The valve's main stage orifice is drilled into the piston, enhancing its durability for physically demanding applications. The PBHFQQV model is compatible with three-port pressure reducing and reducing-relieving cartridges, offering physical interchangeability with the same flow path and cavity for a given frame size. For mounting configurations, using a full capacity return line port 3 with reducing-relieving cartridges is sometimes recommended. The valve allows full reverse flow from reduced pressure port 1 to inlet port 2, but if reverse free flow is required in the circuit, adding a separate check valve is advisable. If pilot flow consumption is critical, direct-acting reducing-relieving valves should be considered. The maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested up to 2000 psi (140 bar), ranges A, B, and H up to 3000 psi (210 bar), and ranges C and W up to 5000 psi (350 bar). Pilot-operated valves like this one exhibit flat pressure-flow characteristics, stability, and low hysteresis. Pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Although not fast-acting by nature compared to direct-acting valves, this model incorporates Sun's floating style construction to minimize internal parts binding due to excessive installation torque or machining variations. It features a T-17A cavity series with a capacity of 40 gpm (160 L/min) and has specific installation torque requirements for optimal performance.
The Sun Hydraulics PBHFQQV (PBHFQQV) is a pilot-operated pressure reducing valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1. This feature allows circuits with multiple pressure requirements to be operated using a single pump, making it an efficient choice for various hydraulic applications. The valve's main stage orifice is drilled into the piston, enhancing its durability for physically demanding applications. The PBHFQQV model is compatible with three-port pressure reducing and reducing-relieving cartridges, offering physical interchangeability with the same flow path and cavity for a given frame size. For mounting configurations, using a full capacity return line port 3 with reducing-relieving cartridges is sometimes recommended. The valve allows full reverse flow from reduced pressure port 1 to inlet port 2, but if reverse free flow is required in the circuit, adding a separate check valve is advisable. If pilot flow consumption is critical, direct-acting reducing-relieving valves should be considered. The maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested up to 2000 psi (140 bar), ranges A, B, and H up to 3000 psi (210 bar), and ranges C and W up to 5000 psi (350 bar). Pilot-operated valves like this one exhibit flat pressure-flow characteristics, stability, and low hysteresis. Pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Although not fast-acting by nature compared to direct-acting valves, this model incorporates Sun's floating style construction to minimize internal parts binding due to excessive installation torque or machining variations. It features a T-17A cavity series with a capacity of 40 gpm (160 L/min) and has specific installation torque requirements for optimal performance.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 40 gpm160 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.30 lb0,60 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction