***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHFWAN (PBHFWAN) is a pilot-operated, pressure-reducing valve designed to manage circuits with varying pressure requirements using a single pump. It reduces high primary pressure at inlet port 2 to a consistent lower pressure at port 1. The valve features a main stage orifice integrated into the piston, enhancing durability for demanding applications. This model is interchangeable with other three-port pressure reducing and reducing-relieving cartridges of the same frame size, allowing flexibility in mounting configurations. Utilizing a full capacity return line port 3 is recommended when using reducing-relieving cartridges. If reverse free flow from reduced pressure port 1 to inlet port 2 is necessary, incorporating a separate check valve is advisable. The PBHFWAN model supports varying adjustment ranges: D, E, N, and Q ranges are suitable for up to 2000 psi (140 bar) maximum differential; A, B, and H ranges handle up to 3000 psi (210 bar); while C and W ranges accommodate up to 5000 psi (350 bar) inlet pressure. The valve exhibits stable performance with low hysteresis due to its flat pressure-flow characteristics. However, it may not be suitable for applications requiring fast dynamic response; direct acting valves are recommended in such cases. The PBHFWAN incorporates Sun's floating style construction which minimizes internal binding risks due to installation torque or machining variations. It has a capacity of 40 gpm (160 L/min), maximum operating pressure of 5000 psi (350 bar), and control pilot flow between 15-20 in\u00b3/min (0.25-0.33 L/min). Installation requires specific torque settings: valve installation torque is between 150-160 lbf\u00b7ft (203-217 Nm), with locknut torque at 80-90 lbf\u00b7in (9-10 Nm).

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg
Seal kit - CartridgeViton: 990-017-006