SUN HYDRAULICS
PBHFYAV
$242.74 USD
- SUN HYDRAULICS
- Material:PBHFYAV
- Model:PBHF-YAV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBHFYAV (PBHFYAV) is a pilot-operated, pressure-reducing valve designed to manage high inlet pressures and maintain a steady reduced pressure at the outlet. This model is engineered for circuits requiring multiple pressure levels using a single pump, offering versatility and efficiency in hydraulic systems. The main orifice is drilled directly into the piston, enhancing durability for demanding applications. The PBHFYAV features interchangeable three-port pressure reducing and relieving cartridges, which simplifies installation across various configurations. For optimal performance, a full capacity return line port is recommended when using reducing-relieving cartridges. This valve supports full reverse flow from the reduced pressure port to the inlet port; however, adding a separate check valve is advisable if reverse free flow is needed. The PBHFYAV accommodates a range of inlet pressures determined by its adjustment settings: Ranges D, E, N, and Q support up to 2000 psi differential; Ranges A, B, and H handle 3000 psi; while Ranges C and W are tested with 5000 psi. Known for their stable performance and low hysteresis, these valves exhibit flat pressure-flow characteristics but are not intended for rapid response applications\u2014direct-acting valves are recommended for faster dynamic responses. The design incorporates Sun's floating style construction to prevent internal part binding due to excessive torque or machining variations. It has a capacity of 40 gpm (160 L/min) and operates up to 5000 psi (350 bar). The control pilot flow ranges between 15-20 in\u00b3/min (0.25-0.33 L/min), with adjustment capabilities via an internal hex screw. This robust component weighs approximately 1.30 lb (0.60 kg) and includes Viton seal kits for enhanced durability in hydraulic systems.
The Sun Hydraulics PBHFYAV (PBHFYAV) is a pilot-operated, pressure-reducing valve designed to manage high inlet pressures and maintain a steady reduced pressure at the outlet. This model is engineered for circuits requiring multiple pressure levels using a single pump, offering versatility and efficiency in hydraulic systems. The main orifice is drilled directly into the piston, enhancing durability for demanding applications. The PBHFYAV features interchangeable three-port pressure reducing and relieving cartridges, which simplifies installation across various configurations. For optimal performance, a full capacity return line port is recommended when using reducing-relieving cartridges. This valve supports full reverse flow from the reduced pressure port to the inlet port; however, adding a separate check valve is advisable if reverse free flow is needed. The PBHFYAV accommodates a range of inlet pressures determined by its adjustment settings: Ranges D, E, N, and Q support up to 2000 psi differential; Ranges A, B, and H handle 3000 psi; while Ranges C and W are tested with 5000 psi. Known for their stable performance and low hysteresis, these valves exhibit flat pressure-flow characteristics but are not intended for rapid response applications\u2014direct-acting valves are recommended for faster dynamic responses. The design incorporates Sun's floating style construction to prevent internal part binding due to excessive torque or machining variations. It has a capacity of 40 gpm (160 L/min) and operates up to 5000 psi (350 bar). The control pilot flow ranges between 15-20 in\u00b3/min (0.25-0.33 L/min), with adjustment capabilities via an internal hex screw. This robust component weighs approximately 1.30 lb (0.60 kg) and includes Viton seal kits for enhanced durability in hydraulic systems.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 40 gpm160 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.30 lb0,60 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction