SUN HYDRAULICS
PBJBLJN
$359.49 USD
- SUN HYDRAULICS
- Material:PBJBLJN
- Model:PBJB-LJN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJBLJN (PBJBLJN) is a pilot-operated pressure reducing valve designed to regulate high primary pressure at the inlet port to a consistent reduced pressure at the output port. This valve is particularly useful in circuits with multiple pressure requirements, allowing for efficient operation using a single pump. It features three-port pressure reducing and reducing-relieving cartridges that are interchangeable, ensuring compatibility across various configurations. For optimal performance, it is recommended to use a full capacity return line port with reducing-relieving cartridges. The valve includes a main stage orifice protected by a 150-micron stainless steel screen and operates with maximum inlet pressures determined by the adjustment range, offering several options: 2000 psi for ranges D, E, N, and Q; 3000 psi for ranges A, B, and H; and up to 5000 psi for ranges C and W. This pilot-operated valve is known for its exceptionally flat pressure-flow characteristics, stability, and low hysteresis. It should be noted that these valves are not fast-acting; thus, direct-acting valves may be preferred for superior dynamic response. Additionally, the valve incorporates Sun's floating style construction to minimize internal parts binding due to excessive installation torque or machining variations. The PBJBLJN model supports a maximum operating pressure of 5000 psi and has a control pilot flow between 15-20 in\u00b3/min. It requires specific installation torque settings and comes equipped with Viton seals suitable for certain fluid types but not petroleum-based substances. This product is ideal for applications demanding precise pressure regulation while maintaining system stability under varying operational conditions.
The Sun Hydraulics PBJBLJN (PBJBLJN) is a pilot-operated pressure reducing valve designed to regulate high primary pressure at the inlet port to a consistent reduced pressure at the output port. This valve is particularly useful in circuits with multiple pressure requirements, allowing for efficient operation using a single pump. It features three-port pressure reducing and reducing-relieving cartridges that are interchangeable, ensuring compatibility across various configurations. For optimal performance, it is recommended to use a full capacity return line port with reducing-relieving cartridges. The valve includes a main stage orifice protected by a 150-micron stainless steel screen and operates with maximum inlet pressures determined by the adjustment range, offering several options: 2000 psi for ranges D, E, N, and Q; 3000 psi for ranges A, B, and H; and up to 5000 psi for ranges C and W. This pilot-operated valve is known for its exceptionally flat pressure-flow characteristics, stability, and low hysteresis. It should be noted that these valves are not fast-acting; thus, direct-acting valves may be preferred for superior dynamic response. Additionally, the valve incorporates Sun's floating style construction to minimize internal parts binding due to excessive installation torque or machining variations. The PBJBLJN model supports a maximum operating pressure of 5000 psi and has a control pilot flow between 15-20 in\u00b3/min. It requires specific installation torque settings and comes equipped with Viton seals suitable for certain fluid types but not petroleum-based substances. This product is ideal for applications demanding precise pressure regulation while maintaining system stability under varying operational conditions.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 2.90 lb1,30 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure