SUN HYDRAULICS
PBJBQAV
$370.41 USD
- SUN HYDRAULICS
- Material:PBJBQAV
- Model:PBJB-QAV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJBQAV (Material Number: PBJBQAV) is a pilot-operated pressure reducing valve designed to reduce a high primary pressure at the inlet port to a constant reduced pressure at the outlet port. This allows circuits with varying pressure requirements to be operated using a single pump. The valve is physically interchangeable with all three-port pressure reducing and reducing-relieving cartridges of the same frame size, offering flexibility in circuit design. It features a full capacity return line port for configurations using reducing-relieving cartridges, and reverse flow from reduced pressure port to inlet may require an additional check valve. The main stage orifice is protected by a 150-micron stainless steel screen, ensuring durability and reliability. The recommended maximum inlet pressure varies by adjustment range, with ranges A, B, and H tested up to 3000 psi differential, while ranges C and W can handle up to 5000 psi. The valve exhibits stable performance with low hysteresis due to its exceptionally flat pressure-flow characteristics. It incorporates Sun's floating style construction to minimize internal part binding during installation or due to machining variations. This model is not fast-acting; for applications requiring superior dynamic response, direct-acting valves are recommended. Cartridges configured with EPDM seals are suitable for systems using phosphate ester fluids but are incompatible with petroleum-based fluids. The PBJBQAV offers robust construction with a factory pressure setting established at blocked control ports and supports control pilot flow rates between 15-20 in\u00b3/min (0.25-0.33 L/min). It includes an adjustment screw for fine-tuning settings and is designed for easy installation with specified torque requirements.
The Sun Hydraulics PBJBQAV (Material Number: PBJBQAV) is a pilot-operated pressure reducing valve designed to reduce a high primary pressure at the inlet port to a constant reduced pressure at the outlet port. This allows circuits with varying pressure requirements to be operated using a single pump. The valve is physically interchangeable with all three-port pressure reducing and reducing-relieving cartridges of the same frame size, offering flexibility in circuit design. It features a full capacity return line port for configurations using reducing-relieving cartridges, and reverse flow from reduced pressure port to inlet may require an additional check valve. The main stage orifice is protected by a 150-micron stainless steel screen, ensuring durability and reliability. The recommended maximum inlet pressure varies by adjustment range, with ranges A, B, and H tested up to 3000 psi differential, while ranges C and W can handle up to 5000 psi. The valve exhibits stable performance with low hysteresis due to its exceptionally flat pressure-flow characteristics. It incorporates Sun's floating style construction to minimize internal part binding during installation or due to machining variations. This model is not fast-acting; for applications requiring superior dynamic response, direct-acting valves are recommended. Cartridges configured with EPDM seals are suitable for systems using phosphate ester fluids but are incompatible with petroleum-based fluids. The PBJBQAV offers robust construction with a factory pressure setting established at blocked control ports and supports control pilot flow rates between 15-20 in\u00b3/min (0.25-0.33 L/min). It includes an adjustment screw for fine-tuning settings and is designed for easy installation with specified torque requirements.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 2.90 lb1,30 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure