SUN HYDRAULICS
PBJBWHV
$375.38 USD
- SUN HYDRAULICS
- Material:PBJBWHV
- Model:PBJB-WHV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJBWHV (PBJBWHV) is a pilot-operated pressure reducing valve designed to manage high primary pressure at the inlet port and maintain a constant reduced pressure at the outlet port. This feature allows for efficient operation of circuits with multiple pressure requirements using a single pump. The valve is physically interchangeable with all three-port pressure reducing and reducing-relieving cartridges, maintaining the same flow path and cavity for a given frame size. It is recommended to use a full capacity return line port with reducing-relieving cartridges for optimal performance. The valve's main stage orifice is protected by a 150-micron stainless steel screen, ensuring durability and reliability. The maximum recommended inlet pressure varies by adjustment range: Ranges D, E, N, and Q are tested with up to 2000 psi differential; A, B, and H ranges can handle up to 3000 psi; while C and W ranges are suitable for pressures up to 5000 psi. The PBJBWHV model exhibits stable performance with low hysteresis due to its flat pressure-flow characteristics. However, it should be noted that pilot-operated valves are not fast-acting; for quicker dynamic response, direct-acting valves are suggested. The valve incorporates Sun's floating style construction to minimize internal part binding from excessive installation torque or machining variations. It features an adjustment mechanism that allows fine-tuning of settings through clockwise turns of the adjustment screw. To ensure compatibility with specific fluid types, cartridges configured with EPDM seals are available for systems using phosphate ester fluids only. With a maximum operating pressure of 5000 psi and factory settings established at blocked control ports, this model provides robust solutions for complex hydraulic systems requiring precise pressure regulation.
The Sun Hydraulics PBJBWHV (PBJBWHV) is a pilot-operated pressure reducing valve designed to manage high primary pressure at the inlet port and maintain a constant reduced pressure at the outlet port. This feature allows for efficient operation of circuits with multiple pressure requirements using a single pump. The valve is physically interchangeable with all three-port pressure reducing and reducing-relieving cartridges, maintaining the same flow path and cavity for a given frame size. It is recommended to use a full capacity return line port with reducing-relieving cartridges for optimal performance. The valve's main stage orifice is protected by a 150-micron stainless steel screen, ensuring durability and reliability. The maximum recommended inlet pressure varies by adjustment range: Ranges D, E, N, and Q are tested with up to 2000 psi differential; A, B, and H ranges can handle up to 3000 psi; while C and W ranges are suitable for pressures up to 5000 psi. The PBJBWHV model exhibits stable performance with low hysteresis due to its flat pressure-flow characteristics. However, it should be noted that pilot-operated valves are not fast-acting; for quicker dynamic response, direct-acting valves are suggested. The valve incorporates Sun's floating style construction to minimize internal part binding from excessive installation torque or machining variations. It features an adjustment mechanism that allows fine-tuning of settings through clockwise turns of the adjustment screw. To ensure compatibility with specific fluid types, cartridges configured with EPDM seals are available for systems using phosphate ester fluids only. With a maximum operating pressure of 5000 psi and factory settings established at blocked control ports, this model provides robust solutions for complex hydraulic systems requiring precise pressure regulation.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 2.90 lb1,30 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure