SUN HYDRAULICS
PBJBYJV


$392.26 USD
  • SUN HYDRAULICS
  • Material:PBJBYJV
  • Model:PBJB-YJV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJBYJV (PBJBYJV) is a pilot-operated, pressure-reducing valve designed to lower a high primary pressure at the inlet port to a consistent reduced pressure at the output port. This feature allows the operation of circuits with varying pressure requirements using a single pump. The valve is part of a series where all three-port pressure-reducing and reducing-relieving cartridges are physically interchangeable, sharing the same flow path and cavity for similar frame sizes. It is recommended that when considering mounting configurations, a full-capacity return line port be utilized with reducing-relieving cartridges to ensure optimal performance. The valve allows for full reverse flow from the reduced pressure port to the inlet port, but this may cause the main spool to close. If reverse free flow is necessary in your circuit, incorporating an additional check valve is advisable. Pilot flow consumption can be critical; therefore, direct-acting reducing-relieving valves might be considered for applications where this is a concern. The Sun Hydraulics PBJBYJV features an orifice protected by a 150-micron stainless steel screen and exhibits exceptionally flat pressure-flow characteristics with low hysteresis, ensuring stability. The maximum recommended inlet pressure varies by adjustment range: Ranges D, E, N, and Q are tested with up to 2000 psi differential; Ranges A, B, and H allow up to 3000 psi; while Ranges C and W support up to 5000 psi. This model incorporates Sun's floating style construction which minimizes potential internal binding due to excessive installation torque or machining variations. Additionally, it includes EPDM seals suitable for systems utilizing phosphate ester fluids but should not be exposed to petroleum-based substances as they could damage the seals. The PBJBYJV also features easy-to-adjust settings with specific torque requirements for its installation components.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight2.90 lb1,30 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure