SUN HYDRAULICS
PBJBYNV
$391.26 USD
- SUN HYDRAULICS
- Material:PBJBYNV
- Model:PBJB-YNV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJBYNV (PBJBYNV) is a pilot-operated, pressure-reducing valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1, allowing for efficient operation of circuits with varying pressure requirements using a single pump. This valve is part of Sun's Series 4 and features a three-port design that is physically interchangeable with other reducing and reducing-relieving cartridges within the same frame size. The PBJBYNV model allows for full reverse flow from reduced pressure port 1 to inlet port 2, although this may cause the main spool to close; thus, adding a separate check valve is recommended if reverse free flow is needed. The main stage orifice of the valve is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability in various applications. The maximum operating pressure for this model is up to 5000 psi (350 bar), with control pilot flow ranging from 15 to 20 in\u00b3/min (0.25 to 0.33 L/min). The valve exhibits exceptionally flat pressure-flow characteristics, providing stability and low hysteresis. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or cavity/cartridge machining variations. This model also allows for easy adjustment with an internal hex size of 5/32 inches and includes EPDM seals suitable for systems using phosphate ester fluids. For applications requiring superior dynamic response, direct-acting valves are suggested as pilot-operated valves like the PBJBYNV are not fast-acting by nature. The cartridge's seal kit is available in Viton under part number 990019006, ensuring compatibility and longevity in demanding environments.
The Sun Hydraulics PBJBYNV (PBJBYNV) is a pilot-operated, pressure-reducing valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1, allowing for efficient operation of circuits with varying pressure requirements using a single pump. This valve is part of Sun's Series 4 and features a three-port design that is physically interchangeable with other reducing and reducing-relieving cartridges within the same frame size. The PBJBYNV model allows for full reverse flow from reduced pressure port 1 to inlet port 2, although this may cause the main spool to close; thus, adding a separate check valve is recommended if reverse free flow is needed. The main stage orifice of the valve is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability in various applications. The maximum operating pressure for this model is up to 5000 psi (350 bar), with control pilot flow ranging from 15 to 20 in\u00b3/min (0.25 to 0.33 L/min). The valve exhibits exceptionally flat pressure-flow characteristics, providing stability and low hysteresis. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or cavity/cartridge machining variations. This model also allows for easy adjustment with an internal hex size of 5/32 inches and includes EPDM seals suitable for systems using phosphate ester fluids. For applications requiring superior dynamic response, direct-acting valves are suggested as pilot-operated valves like the PBJBYNV are not fast-acting by nature. The cartridge's seal kit is available in Viton under part number 990019006, ensuring compatibility and longevity in demanding environments.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 2.90 lb1,30 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure