SUN HYDRAULICS
PBJFKWV
$392.26 USD
- SUN HYDRAULICS
- Material:PBJFKWV
- Model:PBJF-KWV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJFKWV (PBJFKWV) is a pilot-operated pressure reducing valve designed to lower a high primary pressure at the inlet port 2 to a consistent reduced pressure at port 1, enabling efficient operation of circuits with varying pressure needs using a single pump. This valve features a main stage orifice drilled directly into the piston, enhancing its durability in demanding applications. It is crucial to note that cartridges configured with EPDM seals are suitable for systems utilizing phosphate ester fluids; exposure to petroleum-based fluids can damage these seals. The valve allows full reverse flow from port 1 to port 2 but may require an additional check valve if reverse free flow is necessary in the circuit. The recommended maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested up to a 2000 psi differential and ranges A, B, and H up to 3000 psi. Ranges C and W accommodate up to 5000 psi inlet pressure. Known for their stability and low hysteresis, these valves exhibit flat pressure-flow characteristics. However, they are not fast-acting; for quicker response times, direct acting valves are suggested. This model incorporates Sun's floating style construction to prevent internal parts from binding due to excessive torque or machining variations. The PBJFKWV has a capacity of 80 gpm (320 L/min) and operates at a maximum pressure of 5000 psi (350 bar). It requires an installation torque of 350-375 lbf ft (474-508 Nm) and weighs approximately 2.90 lb (1.30 kg). For maintenance or replacements, the Viton seal kit number is 990019006.
The Sun Hydraulics PBJFKWV (PBJFKWV) is a pilot-operated pressure reducing valve designed to lower a high primary pressure at the inlet port 2 to a consistent reduced pressure at port 1, enabling efficient operation of circuits with varying pressure needs using a single pump. This valve features a main stage orifice drilled directly into the piston, enhancing its durability in demanding applications. It is crucial to note that cartridges configured with EPDM seals are suitable for systems utilizing phosphate ester fluids; exposure to petroleum-based fluids can damage these seals. The valve allows full reverse flow from port 1 to port 2 but may require an additional check valve if reverse free flow is necessary in the circuit. The recommended maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested up to a 2000 psi differential and ranges A, B, and H up to 3000 psi. Ranges C and W accommodate up to 5000 psi inlet pressure. Known for their stability and low hysteresis, these valves exhibit flat pressure-flow characteristics. However, they are not fast-acting; for quicker response times, direct acting valves are suggested. This model incorporates Sun's floating style construction to prevent internal parts from binding due to excessive torque or machining variations. The PBJFKWV has a capacity of 80 gpm (320 L/min) and operates at a maximum pressure of 5000 psi (350 bar). It requires an installation torque of 350-375 lbf ft (474-508 Nm) and weighs approximately 2.90 lb (1.30 kg). For maintenance or replacements, the Viton seal kit number is 990019006.
Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 2.90 lb1,30 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations