You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PBJFNCV


$385.30 USD
  • SUN HYDRAULICS
  • Material:PBJFNCV
  • Model:PBJF-NCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBJFNCV (Material Number: PBJFNCV) is a pilot-operated pressure reducing valve designed to manage high primary pressures at the inlet port 2, reducing them to a constant lower pressure at port 1. This allows for the operation of circuits with varying pressure needs using a single pump. The valve features a main stage orifice drilled into the piston, enhancing its durability in physically demanding applications. It is equipped with EPDM seals suitable for systems utilizing phosphate ester fluids; these seals are not compatible with petroleum-based fluids, greases, or lubricants. The valve offers full reverse flow capability from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close. For circuits requiring reverse free flow, incorporating an additional check valve is advisable. The PBJFNCV model exhibits exceptionally flat pressure-flow characteristics and maintains stability with low hysteresis. It supports maximum operating pressures up to 5000 psi (350 bar) and operates with control pilot flows between 15 - 20 in\u00b3/min (0.25 - 0.33 L/min). The adjustment range determines the recommended maximum inlet pressure; ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H handle up to 3000 psi (210 bar), and ranges C and W accommodate pressures of up to 5000 psi (350 bar). This valve incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations in the cavity/cartridge interface. It is physically interchangeable within its series for ease of integration into existing systems. The PBJFNCV model weighs approximately 2.90 lb (1.30 kg) and requires specific torque settings for installation and adjustment operations as detailed in its specifications.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight2.90 lb1,30 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources