You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPDBCCV


$100.97 USD
  • SUN HYDRAULICS
  • Material:PPDBCCV
  • Model:PPDB-CCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDBCCV (Material Number: PPDBCCV) is a pilot-operated, pressure-reducing/relieving valve designed to maintain a consistent reduced pressure from a higher primary pressure. It features a full-flow relief function from port 1 to tank port 3 and is interchangeable with other three-port reducing and reducing/relieving cartridges of the same frame size. For optimal performance, it is recommended to use a full-capacity return line at port 3 when employing this valve type. The valve supports full reverse flow from reduced pressure port 1 to inlet port 2, although this may cause the main spool to close; hence, adding a separate check valve might be necessary if reverse free flow is required. The PPDBCCV can handle maximum inlet pressures determined by its adjustment range, with specific ranges tested for differential pressures up to 5000 psi (350 bar). This valve exhibits stable and low hysteresis characteristics due to its pilot-operated nature but may not be suitable for applications requiring rapid dynamic response\u2014direct-acting valves are recommended in such cases. Additionally, the pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). The cartridge incorporates Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. It comes equipped with EPDM seals suitable for phosphate ester fluids but should avoid petroleum-based substances that could damage the seals. With a capacity of 10 gpm (40 L/min), this valve operates under maximum pressures of up to 5000 psi (350 bar) and features various adjustment options for precise control settings.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.