SUN HYDRAULICS
PPDBODV
$107.92 USD
- SUN HYDRAULICS
- Material:PPDBODV
- Model:PPDB-ODV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDBODV (Material Number: PPDBODV) is a pilot-operated, pressure-reducing/relieving valve designed to manage high primary pressure at inlet port 2, reducing it to a constant lower pressure at port 1, and offering full-flow relief to tank port 3. This three-port cartridge is interchangeable with others of the same frame size and flow path. It is recommended that full capacity return line port 3 be used with reducing/relieving cartridges. The valve allows reverse flow from reduced pressure port 1 to inlet port 2, though this may close the main spool; a separate check valve may be needed for reverse free flow. If pilot flow consumption is a concern, direct-acting valves are suggested. The valve's maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi; ranges A, B, and H with 3000 psi; and ranges C and W with an inlet pressure of up to 5000 psi. These valves exhibit stable performance with low hysteresis due to their flat pressure-flow characteristics. Port 3's pressure adds directly to the valve setting at a ratio of 1:1 but should not exceed 5000 psi. Notably, these pilot-operated valves are not fast-acting; for better dynamic response, direct-acting valves are recommended. The PPDBODV features Sun's floating style construction to prevent internal binding from excessive installation torque or machining variations in cavity/cartridge assembly. It has a capacity of up to 10 gpm (40 L/min) and operates at pressures up to 5000 psi (350 bar). The model weight is approximately .30 lb (.15 kg), and it uses Viton seals compatible with specific fluid types.
The Sun Hydraulics PPDBODV (Material Number: PPDBODV) is a pilot-operated, pressure-reducing/relieving valve designed to manage high primary pressure at inlet port 2, reducing it to a constant lower pressure at port 1, and offering full-flow relief to tank port 3. This three-port cartridge is interchangeable with others of the same frame size and flow path. It is recommended that full capacity return line port 3 be used with reducing/relieving cartridges. The valve allows reverse flow from reduced pressure port 1 to inlet port 2, though this may close the main spool; a separate check valve may be needed for reverse free flow. If pilot flow consumption is a concern, direct-acting valves are suggested. The valve's maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi; ranges A, B, and H with 3000 psi; and ranges C and W with an inlet pressure of up to 5000 psi. These valves exhibit stable performance with low hysteresis due to their flat pressure-flow characteristics. Port 3's pressure adds directly to the valve setting at a ratio of 1:1 but should not exceed 5000 psi. Notably, these pilot-operated valves are not fast-acting; for better dynamic response, direct-acting valves are recommended. The PPDBODV features Sun's floating style construction to prevent internal binding from excessive installation torque or machining variations in cavity/cartridge assembly. It has a capacity of up to 10 gpm (40 L/min) and operates at pressures up to 5000 psi (350 bar). The model weight is approximately .30 lb (.15 kg), and it uses Viton seals compatible with specific fluid types.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.