You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPDFCKN


$92.03 USD
  • SUN HYDRAULICS
  • Material:PPDFCKN
  • Model:PPDF-CKN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDFCKN (Material Number: PPDFCKN) is a pilot-operated, pressure reducing/relieving valve designed to maintain a consistent reduced pressure at port 1 while offering full-flow relief from port 1 to tank port 3. This valve features a unique design with the main stage orifice drilled directly into the piston, enhancing its durability in demanding applications. The maximum pressure at port 3 is capped at 3000 psi (210 bar), and this pressure is directly additive to the valve setting at a 1:1 ratio. The recommended maximum inlet pressures vary based on adjustment ranges, with ranges D, E, N, and Q tested at a maximum differential of 2000 psi (140 bar), while ranges A, B, and H can handle up to 3000 psi (210 bar), and ranges C and W are tested for up to 5000 psi (350 bar). These valves exhibit stable performance with low hysteresis and exceptionally flat pressure-flow characteristics. For applications requiring reverse free flow from reduced pressure port 1 to inlet port 2, it is advisable to incorporate a separate check valve in the circuit as the main spool may close under such conditions. The PPDFCKN model incorporates Sun's floating style construction which minimizes internal binding due to installation torque or machining variations. It has a capacity of handling up to 10 gpm (40 L/min) and operates efficiently within a maximum operating pressure of 5000 psi (350 bar). The valve's control pilot flow ranges between 7-10 in\u00b3/min (0.11-0.16 L/min). It requires specific installation torques for optimal performance: valve installation torque should be between 30-35 lbf ft (41-47 Nm), with locknut torque set between 80-90 lbf in (9-10 Nm). The PPDFCKN model weighs approximately .30 lb (.15 kg) and uses Viton seal kits for enhanced sealing capabilities.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.