You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPDFKJV


$106.93 USD
  • SUN HYDRAULICS
  • Material:PPDFKJV
  • Model:PPDF-KJV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDFKJV (PPDFKJV) is a pilot-operated, pressure reducing/relieving valve designed to manage high primary pressure at the inlet port 2, maintaining a constant reduced pressure at port 1, while providing full-flow relief from port 1 to tank port 3. This valve features a main stage orifice drilled into the piston, enhancing its durability in physically demanding applications. It is crucial to limit the maximum pressure at port 3 to 3000 psi (210 bar), as any pressure here directly adds to the valve setting at a 1:1 ratio and should not exceed this threshold. While pilot-operated valves like this one are not fast-acting, they are known for their stable performance and low hysteresis. For applications requiring superior dynamic response, direct-acting valves are recommended. The PPDFKJV is tested with varying maximum inlet pressures depending on the adjustment range: ranges D, E, N, and Q with up to a 2000 psi (140 bar) differential; ranges A, B, and H with up to a 3000 psi (210 bar) differential; and ranges C and W with an inlet pressure of up to 5000 psi (350 bar). The valve's design allows for interchangeable use across all three-port pressure reducing/relieving cartridges of the same frame size. Reverse flow from reduced pressure port 1 back to inlet port 2 may close the main spool; thus, adding a separate check valve may be necessary if reverse free flow is required. The PPDFKJV incorporates Sun's floating style construction which minimizes internal binding due to installation torque or machining variations. It has a capacity of up to 10 gpm (40 L/min), and its factory pressure settings are established when control ports are blocked or dead-headed. The valve's installation torque ranges between 30-35 lbf\u00b7ft (41-47 Nm), ensuring secure placement within hydraulic systems.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.