You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPDFOWN


$97.99 USD
  • SUN HYDRAULICS
  • Material:PPDFOWN
  • Model:PPDF-OWN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDFOWN (Material Number: PPDFOWN) is a pilot-operated, pressure reducing-relieving valve designed for demanding hydraulic applications. This valve effectively reduces high primary pressure at the inlet port 2 to a consistent lower pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. Notably, the main stage orifice is drilled into the piston rather than being staked-in, enhancing its durability in physically challenging environments. It is crucial to limit the maximum pressure at port 3 to 3000 psi (210 bar), with any pressure at this port directly adding to the valve setting in a 1:1 ratio. The valve demonstrates exceptional stability and low hysteresis due to its flat pressure-flow characteristics, although it is not as fast-acting as direct-acting valves. For optimal performance, recommended maximum inlet pressures vary by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H can handle up to 3000 psi (210 bar). Ranges C and W accommodate inlet pressures up to 5000 psi (350 bar). The valve allows full reverse flow from reduced pressure port 1 to inlet port 2 but may cause the main spool to close; thus, incorporating a separate check valve is advisable if reverse free flow is necessary. The PPDFOWN model incorporates Sun's floating style construction to minimize internal binding risks due to installation torque or machining variations. This Series 1 cartridge has a capacity of 10 gpm (40 L/min) and operates up to a maximum pressure of 5000 psi (350 bar). The control pilot flow ranges between 7\u201310 in\u00b3/min (0.11\u20130.16 L/min), with adjustable settings achievable through clockwise turns of an internal hex screw.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes: