SUN HYDRAULICS
PPDFQCN
$91.04 USD
- SUN HYDRAULICS
- Material:PPDFQCN
- Model:PPDF-QCN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPDFQCN (PPDFQCN) is a pilot-operated, pressure-reducing and relieving valve designed to manage high primary pressures at the inlet port 2, reducing them to a stable lower pressure at port 1 while offering full-flow relief from port 1 to tank port 3. Notably, the main stage orifice is drilled into the piston, enhancing durability in demanding applications. The valve can handle a maximum pressure of 3000 psi (210 bar) at port 3, which also directly influences the valve setting on a 1:1 ratio basis. It is important to note that this model is not fast-acting due to its pilot-operated nature; for applications requiring superior dynamic response, direct-acting valves are recommended. The PPDFQCN model exhibits flat pressure-flow characteristics with low hysteresis and stability. It allows reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close unless a separate check valve is integrated into the circuit. For those concerned about pilot flow consumption, direct acting reducing-relieving valves might be more suitable. This cartridge-style valve fits within a T-11A cavity and has a series capacity of up to 10 gpm (40 L/min). With factory-established pressure settings when control ports are dead-headed and an operating pressure capacity of up to 5000 psi (350 bar), it provides reliable performance across various settings. The control pilot flow ranges between 7 - 10 in\u00b3/min (0.11 - 0.16 L/min), with an adjustment mechanism that requires approximately five turns clockwise to increase the setting. For installation, it demands torque specifications between 30 -35 lbf ft (41 -47 Nm) for the valve and uses Viton seals as part of its standard cartridge configuration. Its weight stands at .30 lbs (0.15 kg), making it relatively lightweight for its capabilities in hydraulic systems management.
The Sun Hydraulics PPDFQCN (PPDFQCN) is a pilot-operated, pressure-reducing and relieving valve designed to manage high primary pressures at the inlet port 2, reducing them to a stable lower pressure at port 1 while offering full-flow relief from port 1 to tank port 3. Notably, the main stage orifice is drilled into the piston, enhancing durability in demanding applications. The valve can handle a maximum pressure of 3000 psi (210 bar) at port 3, which also directly influences the valve setting on a 1:1 ratio basis. It is important to note that this model is not fast-acting due to its pilot-operated nature; for applications requiring superior dynamic response, direct-acting valves are recommended. The PPDFQCN model exhibits flat pressure-flow characteristics with low hysteresis and stability. It allows reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close unless a separate check valve is integrated into the circuit. For those concerned about pilot flow consumption, direct acting reducing-relieving valves might be more suitable. This cartridge-style valve fits within a T-11A cavity and has a series capacity of up to 10 gpm (40 L/min). With factory-established pressure settings when control ports are dead-headed and an operating pressure capacity of up to 5000 psi (350 bar), it provides reliable performance across various settings. The control pilot flow ranges between 7 - 10 in\u00b3/min (0.11 - 0.16 L/min), with an adjustment mechanism that requires approximately five turns clockwise to increase the setting. For installation, it demands torque specifications between 30 -35 lbf ft (41 -47 Nm) for the valve and uses Viton seals as part of its standard cartridge configuration. Its weight stands at .30 lbs (0.15 kg), making it relatively lightweight for its capabilities in hydraulic systems management.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.