***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPFBLHE (PPFBLHE) is a pilot-operated, pressure reducing/relieving valve designed to maintain a consistent reduced pressure from a higher primary pressure at the inlet port 2 to port 1, while also offering a full-flow relief function to tank port 3. This valve is engineered with exceptional stability and low hysteresis, making it suitable for applications requiring precise pressure control. It features maximum operating pressures of up to 5000 psi (350 bar) and can handle various pressure differentials depending on the adjustment range, such as 3000 psi (210 bar) for ranges A and B, and up to 5000 psi (350 bar) for range W. The valve incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or machining variations. It is adjustable throughout its full range using W or Y controls unless a special setting is specified. The valve's design allows it to exhibit flat pressure-flow characteristics but is not intended for fast-acting applications; direct-acting valves are recommended for superior dynamic response. For systems utilizing phosphate ester fluids, cartridges configured with EPDM seals are recommended, as exposure to petroleum-based fluids can damage these seals. The PPFBLHE model ensures interchangeability among all three-port pressure reducing and relieving cartridges within the same frame size. It supports full reverse flow from reduced pressure port 1 to inlet port 2 without causing the main spool to close; however, adding a separate check valve may be necessary if free reverse flow is required in the circuit. The cartridge installation requires specific torque settings: valve hex size of 1-1/8 inches with an installation torque of 45-50 lbf ft (61-68 Nm), adjustment screw internal hex size of 5/32 inches, and locknut hex size of 9/16 inches with a torque of 80-90 lbf in (9-10 Nm).

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg