You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPFBLWE


$427.50 USD
  • SUN HYDRAULICS
  • Material:PPFBLWE
  • Model:PPFB-LWE
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPFBLWE (PPFBLWE) is a pilot-operated, pressure reducing-relieving valve designed to reduce a high primary pressure at the inlet port 2 to a consistent reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve is suitable for systems requiring stable performance with low hysteresis, though it is not intended for fast-acting applications; direct-acting valves are recommended for those scenarios. The maximum allowable pressure at port 3 should not exceed 3000 psi (210 bar), and the recommended maximum inlet pressure varies by adjustment range. The PPFBLWE model features exceptionally flat pressure-flow characteristics and incorporates Sun's floating style construction, minimizing the risk of internal parts binding due to excessive installation torque or machining variations. It supports reverse flow from reduced pressure port 1 to inlet port 2, although this may cause the main spool to close; adding a separate check valve can address this issue if needed. The valve is adjustable throughout its full range using W or Y controls unless a special setting is specified, which then represents the maximum setting. It includes EPDM seals suitable for phosphate ester fluids but should avoid petroleum-based substances that could damage the seals. The unit has a capacity of 20 gpm (80 L/min) and operates effectively within pressures up to 5000 psi (350 bar). Installation requires specific torque settings for both the valve and locknut, ensuring proper operation and longevity of the component in hydraulic systems.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.