PPFBYBN


$149.22 USD
  • SUN HYDRAULICS
  • Material:PPFBYBN
  • Model:PPFB-YBN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPFBYBN (PPFBYBN) is a pilot-operated, pressure-reducing and relieving valve designed to manage high primary pressures at inlet port 2, reducing them to a consistent lower pressure at port 1, while providing full-flow relief from port 1 to tank port 3. This valve is ideal for applications requiring stable pressure control with low hysteresis and flat pressure-flow characteristics. It is important to note that the maximum pressure at port 3 should not exceed 3000 psi (210 bar), and the recommended maximum inlet pressure varies depending on the adjustment range. The PPFBYBN model is tested for different ranges with specific maximum differential pressures between inlet and reduced pressures, ensuring optimal performance across various settings. The valve features Sun's floating style construction to minimize binding risks due to installation torque or machining variations. It incorporates EPDM seals suitable for systems using phosphate ester fluids but should be avoided in petroleum-based environments. The interchangeable design of these three-port cartridges allows flexibility in mounting configurations, with recommendations for using a full capacity return line for reducing-relieving cartridges. For applications where dynamic response is critical, direct-acting valves are suggested over pilot-operated models like the PPFBYBN. The valve provides reverse flow capability from reduced pressure port 1 to inlet port 2 but may require an additional check valve if free flow is necessary. Installation specifics include a cavity type T-2A, series 2 capacity of 20 gpm (80 L/min), and factory-established settings under blocked conditions. Proper installation torque and adjustment guidelines ensure reliable operation within its specified parameters.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.