***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPFDKEV (Material Number: PPFDKEV) is a pilot-operated, pressure reducing-relieving valve designed to reduce high primary pressure at inlet port 2 to a constant, reduced pressure at port 1, while providing full-flow relief from port 1 to tank port 3. This valve features a .020 inch (0.51 mm) diameter bleed orifice that biases the valve into a reducing mode in dead-headed conditions, enhancing its responsiveness to sudden flow demands. Pressure at port 3 is directly additive to the valve setting in a 1:1 ratio and should not exceed 3000 psi (210 bar). Maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested with a maximum differential of 2000 psi (140 bar), ranges A, B, and H with 3000 psi (210 bar), and ranges C and W with an inlet pressure of up to 5000 psi (350 bar). This valve exhibits stable performance with low hysteresis and flat pressure-flow characteristics. Reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool; hence, adding a separate check valve is advisable if reverse free flow is needed. The PPFDKEV model incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. It fits into cavity T-2A Series 2 with a capacity of up to 20 gpm (80 L/min) and operates up to a maximum pressure of 5000 psi (350 bar). The control pilot flow ranges from 10-15 in\u00b3/min (0.16-0.25 L/min), with adjustments made via an internal hex screw requiring specific torque settings for secure installation.
The Sun Hydraulics PPFDKEV (Material Number: PPFDKEV) is a pilot-operated, pressure reducing-relieving valve designed to reduce high primary pressure at inlet port 2 to a constant, reduced pressure at port 1, while providing full-flow relief from port 1 to tank port 3. This valve features a .020 inch (0.51 mm) diameter bleed orifice that biases the valve into a reducing mode in dead-headed conditions, enhancing its responsiveness to sudden flow demands. Pressure at port 3 is directly additive to the valve setting in a 1:1 ratio and should not exceed 3000 psi (210 bar). Maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested with a maximum differential of 2000 psi (140 bar), ranges A, B, and H with 3000 psi (210 bar), and ranges C and W with an inlet pressure of up to 5000 psi (350 bar). This valve exhibits stable performance with low hysteresis and flat pressure-flow characteristics. Reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool; hence, adding a separate check valve is advisable if reverse free flow is needed. The PPFDKEV model incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. It fits into cavity T-2A Series 2 with a capacity of up to 20 gpm (80 L/min) and operates up to a maximum pressure of 5000 psi (350 bar). The control pilot flow ranges from 10-15 in\u00b3/min (0.16-0.25 L/min), with adjustments made via an internal hex screw requiring specific torque settings for secure installation.
Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- This valve incorporates a .020 (0,51 mm) in. diameter bleed orifice between the reduced pressure and tank. This biases the valve into a reducing mode in a dead headed condition which helps the valve respond to a sudden call for flow.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.