You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPJBLEN


$550.91 USD
  • SUN HYDRAULICS
  • Material:PPJBLEN
  • Model:PPJB-LEN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJBLEN (PPJBLEN) is a pilot-operated, pressure-reducing and relieving valve designed to manage high primary pressures at the inlet port 2 and maintain a constant reduced pressure at port 1, with an integrated relief function to tank port 3. This valve is engineered for applications requiring stable pressure control with low hysteresis, making it suitable for systems where precise pressure regulation is essential. The maximum permissible pressure at port 3 is limited to 3000 psi (210 bar), and any pressure at this port directly adds to the valve setting in a 1:1 ratio. It is important to note that pilot-operated valves like this one are not intended for rapid response situations; direct-acting valves are recommended for superior dynamic response. The PPJBLEN valve supports various adjustment ranges, tested under specific maximum differential pressures between inlet and reduced pressures: Ranges D, E, N, and Q handle up to 2000 psi (140 bar), while Ranges A, B, and H accommodate up to 3000 psi (210 bar). For higher demands, Ranges C and W can withstand an inlet pressure of up to 5000 psi (350 bar). This model features exceptionally flat pressure-flow characteristics and incorporates Sun's floating style construction to reduce the risk of internal binding due to installation torque or machining variations. With a capacity of up to 80 gpm (320 L/min) and operating pressures reaching 5000 psi (350 bar), this valve requires careful consideration of its installation torque specifications\u2014between 350-375 lbf ft (474-508 Nm)\u2014and adjustment settings. The PPJBLEN also includes interchangeable components within its series, ensuring compatibility across various configurations. For scenarios necessitating reverse flow from reduced pressure port 1 back to inlet port 2, it may be necessary to integrate an additional check valve into the circuit.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure