You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPJBWEV


$566.79 USD
  • SUN HYDRAULICS
  • Material:PPJBWEV
  • Model:PPJB-WEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJBWEV (PPJBWEV) is a pilot-operated, pressure reducing-relieving valve designed to manage high primary pressures at inlet port 2, reducing them to a consistent lower pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve is optimal for applications requiring stable pressure reduction with low hysteresis and exceptionally flat pressure-flow characteristics. It supports a maximum operating pressure of 5000 psi (350 bar) and is built for a capacity of up to 80 gpm (320 L/min). The valve's design incorporates Sun's floating style construction, which minimizes internal part binding due to excessive installation torque or machining variations. The PPJBWEV model features several adjustment ranges, with maximum inlet pressures determined by these ranges: Ranges D, E, N, and Q are tested with up to 2000 psi (140 bar) differentials; Ranges A, B, and H allow for up to 3000 psi (210 bar); while Ranges C and W accommodate up to 5000 psi (350 bar). The valve is not fast-acting by nature; hence it may not be suitable for applications demanding rapid response times\u2014direct acting valves are recommended for such needs. For installation considerations, the valve requires a cavity type T-19A with a series size of 4. It has specific torque requirements: installation torque should be between 350 - 375 lbf ft (474 - 508 Nm), with locknut torque set at 80 - 90 lbf in. Additionally, the product allows reverse flow from reduced pressure port 1 to inlet port 2 but may require an additional check valve if free flow in reverse direction is needed. This model weighs approximately 3.10 lb (1.40 kg) and utilizes Viton seals for optimal performance.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure