SUN HYDRAULICS
PPJBWHV


$567.78 USD
  • SUN HYDRAULICS
  • Material:PPJBWHV
  • Model:PPJB-WHV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJBWHV (PPJBWHV) is a pilot-operated pressure reducing/relieving valve designed to manage high primary pressures, ensuring a constant reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. This valve is engineered to handle a maximum operating pressure of 5000 psi (350 bar) and is suitable for applications requiring stable and low-hysteresis performance. The PPJBWHV model exhibits exceptionally flat pressure-flow characteristics, making it highly reliable in maintaining consistent output under varying flow conditions. It is important to note that this type of valve is not fast-acting; for applications demanding superior dynamic response, direct-acting valves are recommended. The design incorporates Sun's floating style construction, minimizing the potential for internal parts binding due to excessive installation torque or machining variations. The valve's cavity is T-19A with a series 4 capacity of 80 gpm (320 L/min), and it features interchangeable cartridges across all three-port configurations, allowing flexibility in system design. The factory pressure settings are established with the control port dead-headed, providing reliable calibration. For optimal performance, the recommended maximum inlet pressure depends on the adjustment range: ranges D, E, N, and Q can handle up to a 2000 psi (140 bar) differential between inlet and reduced pressure, while ranges A, B, and H can manage up to 3000 psi (210 bar), and ranges C and W can withstand an inlet pressure of up to 5000 psi (350 bar). When reverse flow from reduced pressure port 1 to inlet port 2 occurs, the main spool may close; thus, adding a separate check valve might be necessary if reverse free flow is required in the circuit.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure