***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXEV2C12V (PRDMXEV2C12V) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure. This valve is engineered to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1, while also offering a full flow relief function from port 1 to tank port 3. It operates by connecting port 2 to port 1 at a customer-specified pressure setting and can proportionally decrease the reduced pressure at port 1 by increasing the current to the coil. If the pressure at port 1 surpasses the coil-induced setting, it will be relieved to port 3. The valve remains open during transitions from reducing to relieving, ensuring good pressure control and dynamic response. The PRDMXEV2C12V model features a direct-acting concept that provides reliable operation in contaminated systems, especially under dead-headed conditions. It allows for maximum operating pressures of up to 5000 psi (350 bar) and has a capacity of handling flows up to 5 gpm (20 L/min). Coils are interchangeable with other solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. For optimal performance, using an amplifier with current sensing and adjustable dither between 100 - 250 Hz is recommended. The valve\u2019s construction incorporates Sun's floating style design, minimizing potential internal binding due to installation torque or machining variations. It is compatible with all three-port pressure reducing and reducing-relieving cartridges of the same frame size, which are physically interchangeable. This makes it versatile for various mounting configurations where full capacity return line ports are used with reducing-relieving cartridges. Additionally, it offers robust performance with minimal oil consumption of approximately 0.1 gpm (0.4 L/min), making it suitable for applications requiring precise pressure control in hydraulic circuits.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min.330 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006