You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PRDMXSN2D24V


$568.67 USD
  • SUN HYDRAULICS
  • Material:PRDMXSN2D24V
  • Model:PRDM-XSN@2D24V
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXSN2D24V (PRDMXSN2D24V) is an electroproportional, direct-acting reducer-reliever valve designed to manage hydraulic pressure effectively. It reduces high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while also providing a full flow relief function from port 1 to tank port 3. The valve operates in reducing mode by default, linking port 2 to port 1 at a specified pressure setting, and increasing current to the coil decreases the reduced pressure proportionally. If the pressure at port 1 surpasses the coil-induced setting, it is relieved to port 3. This valve ensures precise pressure control and dynamic response during transitions from reducing to relieving modes. Pressure at port 3 can add directly to the valve setting in a 1:1 ratio but should not exceed 3000 psi (210 bar). The direct-acting design is highly reliable in contaminated systems, especially under dead-headed conditions. The transition from reducing to relieving remains slightly open, resulting in efficient pressure control with minimal oil consumption of about 0.1 gpm (0.4 L/min). For optimal performance, an amplifier with adjustable dither between 100-250 Hz is recommended. Coils are interchangeable with Sun's other solenoid-operated valves and can be mounted bidirectionally on the tube. Without an electrical signal, the reduced pressure defaults to the specified value; increasing coil command reduces secondary pressure proportionally. Full reverse flow might close the main spool; hence, adding a separate check valve may be necessary if reverse free flow is required. The three-port cartridges are physically interchangeable across similar frame sizes for ease of configuration. The Sun floating style construction minimizes internal part binding risks due to installation torque or machining variations.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min.330 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ

Additional Resources